Are undesirable contact kinematics minimized after kinematically aligned total knee arthroplasty? An intersurgeon analysis of consecutive patients

被引:73
作者
Howell, Stephen M. [1 ]
Hodapp, Esther E. [1 ]
Vernace, Joseph V.
Hull, Maury L. [1 ]
Meade, Thomas D.
机构
[1] Univ Calif Davis, Dept Mech Engn, Davis, CA 95616 USA
关键词
Total knee arthroplasty; Kneeling; Kinematic alignment; Kinematics; ROTATIONAL ALIGNMENT; REPLACEMENT; COMPONENT;
D O I
10.1007/s00167-012-2220-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Tibiofemoral contact kinematics or knee implant motions have a direct influence on patient function and implant longevity and should be evaluated for any new alignment technique such as kinematically aligned total knee arthroplasty (TKA). Edge loading of the tibial liner and external rotation (reverse of normal) and adduction of the tibial component on the femoral component are undesirable contact kinematics that should be minimized. Accordingly, this study determined whether the overall prevalence of undesirable contact kinematics during standing, mid kneeling near 90 degrees and full kneeling with kinematically aligned TKA are minimal and not different between groups of consecutive patients treated by different surgeons. Three surgeons were asked to perform cemented, kinematically aligned TKA with patient-specific guides in a consecutive series of patients with their preferred cruciate-retaining (CR) implant. In vivo tibiofemoral contact positions were obtained using a 3- to 2-dimensional image registration technique in 69 subjects (Vanguard CR-TKA N = 22, and Triathlon CR-TKA N = 47). Anterior or posterior edge loading of the tibial liner was not observed. The overall prevalence of external rotation of the tibial component on the femoral component of 6 % was low and not different between surgeons (n.s.). The overall prevalence of adduction of the tibial component on the femoral component of 4 % was low and not different between surgeons (n.s.). Kinematically aligned TKA minimized the undesirable contact kinematics of edge loading of the tibial liner, and external rotation and adduction of the tibial component on the femoral component during standing and kneeling, which suggests an optimistic prognosis for durable long-term function. III.
引用
收藏
页码:2281 / 2287
页数:7
相关论文
共 29 条
[11]
Howell SM., 2012, IMPROVING ACCURACY K, P207, DOI DOI 10.5005/JP/BOOKS/11661_15
[12]
Howell SM, 2012, CLIN ORTHOP RELAT RE
[13]
Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients [J].
Howell, Stephen M. ;
Kuznik, Kyle ;
Hull, Maury L. ;
Siston, Robert A. .
ORTHOPEDICS, 2008, 31 (09) :857-863
[14]
Method for Quantifying Patient Expectations and Early Recovery After Total Knee Arthroplasty [J].
Howell, Stephen M. ;
Rogers, Stephanie L. .
ORTHOPEDICS, 2009, 32 (12) :884
[15]
Determining the rotational alignment of the tibial component at total knee replacement - A comparison of two techniques [J].
Ikeuchi, M. ;
Yamanaka, N. ;
Okanoue, Y. ;
Ueta, E. ;
Tani, T. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (01) :45-49
[16]
Tibiofemoral kinematic analysis of kneeling after total knee arthroplasty [J].
Incavo, SJ ;
Mullins, ER ;
Coughlin, KM ;
Banks, S ;
Banks, A ;
Beynnon, BD .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :906-910
[17]
CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714
[18]
Custom-fit total knee arthroplasty (OtisKnee) results in malalignment [J].
Klatt, Brian A. ;
Goyal, Nitin ;
Austin, Matthew S. ;
Hozack, William J. .
JOURNAL OF ARTHROPLASTY, 2008, 23 (01) :26-29
[19]
Miller MC, 2001, CLIN ORTHOP RELAT R, P38
[20]
An analysis of the Oxford hip and knee scores and their relationship to early joint revision in the New Zealand Joint Registry [J].
Rothwell, A. G. ;
Hooper, G. J. ;
Hobbs, A. ;
Frampton, C. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (03) :413-418