A real-time data acquisition system for a hand-held electronic nose (H2EN)

被引:21
作者
Chueh, HT [1 ]
Hatfield, JV [1 ]
机构
[1] UMIST, Dept Elect Engn & Elect, Manchester M60 1QD, Lancs, England
关键词
electronic nose; data acquisition system; calibration; real-time; embedded system; EPOC; portable application;
D O I
10.1016/S0925-4005(01)01059-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes an approach towards the development of a portable E-nose device based on an array of metal oxide sensors NOS) devices, for early on-site dry rot detection on building timbers. A dedicated real-time data acquisition system with a programmable voltage generator, self-calibration techniques and custom visual software programs for a desktop PC and a hand-held computer have been designed and constructed for this application. This paper also describes an example of software calibration to correct source errors for this data acquisition system. Experimental results show that this data acquisition system can accurately measure a large range of resistive sensor responses and is suitable for measuring both conducting polymer and MOS sensors. The custom software also allows users to easily capture, analyse and record measurement data. In addition, the constructed framework for a hand-held computer is based on real-time object-oriented methodology to carry out the functions of desktop PC based instrumentation software. This system presents an effective and user-friendly interface for portable applications. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:262 / 269
页数:8
相关论文
共 14 条
[1]   High-precision intelligent interface for a hybrid electronic nose [J].
Dyer, DC ;
Gardner, JW .
SENSORS AND ACTUATORS A-PHYSICAL, 1997, 62 (1-3) :724-728
[2]   Oscillator-based signal conditioning with improved linearity for resistive sensors [J].
Ferrari, V ;
Ghidini, C ;
Marioli, D ;
Taroni, A .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (01) :293-298
[3]  
GARDNER JW, 1994, SENSOR ACTUAT B-CHEM, V18, P211
[4]  
HATFIELD JV, 1999, P EUROSENSORS HAG NE, V13, P215
[5]   Electronic noses: a review of signal processing techniques [J].
Hines, EL ;
Llobet, E ;
Gardner, JW .
IEE PROCEEDINGS-CIRCUITS DEVICES AND SYSTEMS, 1999, 146 (06) :297-310
[6]   HIGHLY ACCURATE RESISTANCE DEVIATION TO FREQUENCY-CONVERTER WITH PROGRAMMABLE SENSITIVITY AND RESOLUTION [J].
JOHNSON, CD ;
ALRICHEH, H .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1986, 35 (02) :178-181
[7]   Limitations of a relaxation oscillator in capacitance measurements [J].
Liu, YL ;
Chen, S ;
Nakayama, M ;
Watanabe, K .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (05) :980-983
[8]   SENSORS WITH DIGITAL OR FREQUENCY OUTPUT [J].
MIDDELHOEK, S ;
FRENCH, PJ ;
HUIJSING, JH ;
LIAN, WJ .
SENSORS AND ACTUATORS, 1988, 15 (02) :119-133
[9]   A high-resolution, linear resistance-to-frequency converter [J].
Mochizuki, K ;
Watanabe, K .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1996, 45 (03) :761-764
[10]   Measurement of the response of resistive sensors using logic oscillators and integrated frequency measurement [J].
Stone, R ;
Payne, PA .
SENSORS AND ACTUATORS A-PHYSICAL, 1999, 76 (1-3) :431-436