Determination of sulfur isotope ratios and concentrations in water samples using ICP-MS incorporating hexapole ion optics

被引:105
作者
Mason, PRD [1 ]
Kaspers, K [1 ]
van Bergen, MJ [1 ]
机构
[1] Univ Utrecht, Fac Earth Sci, NL-3584 CD Utrecht, Netherlands
关键词
D O I
10.1039/a902037c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sulfur isotope ratios are difficult to determine by quadrupole ICP-MS due to interfering O-2(+) and NO+ molecular ions of high signal intensity at isotopes S-32 and S-34. Rf-only hexapole devices have recently been introduced into ICP-MS instrumentation to facilitate ion transfer from interface to analyser. By introducing a mixture of 'reactive' gases into the hexapole, a series of ion-molecule reactions can be induced to reduce or remove interfering polyatomic species. The effects of various gas mixtures (He, H-2 and Xe) on the transfer of sulfur ions through the hexapole and the breakdown of interfering O-2(+) and NO+ molecular ions at m/z = 32 and m/z = 34 were investigated. A rapid charge transfer reaction between O-2(+) and Xe gives at least a factor of 10 improvement in the S+ /O-2(+) ratio. A further reduction in O-2(+) is achieved by the addition of H-2.delta(34)S variations were investigated in crater-lake waters and waters obtained from springs and rivers on the flanks of volcanoes in Java, Indonesia. Under optimum conditions (S = 10-50 mg l(-1)), the S-34/S-32 measurement precision for standards and samples was <0.3% RSD. Mass bias errors were corrected by using a concentration-matched in-house standard of average North Atlantic sea-water (delta(34)S = 20.5 parts per thousand). Results compare favorably against published data measured by standard gas source mass spectrometric techniques. The proposed technique is potentially useful as a survey tool due to the large delta(34)S variation (+/-20 parts per thousand) encountered in nature and the accuracy and reproducibility of the technique (+/-3-5 parts per thousand).
引用
收藏
页码:1067 / 1074
页数:8
相关论文
共 34 条
[21]  
McDaniel E.W., 1970, ION MOL REACTIONS
[22]   Determination of trace amounts of sulfur in steel by electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Naka, H ;
Gregoire, DC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (05) :359-363
[23]  
PROHASKA T, 1999, EUR WINT C PLASM SPE
[24]   Discrimination of sulfur sources in pristine and polluted New Zealand river catchments using stable isotopes [J].
Robinson, BW ;
Bottrell, SH .
APPLIED GEOCHEMISTRY, 1997, 12 (03) :305-319
[25]   ATTENUATION OF POLYATOMIC ION INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY BY GAS-PHASE COLLISIONS [J].
ROWAN, JT ;
HOUK, RS .
APPLIED SPECTROSCOPY, 1989, 43 (06) :976-980
[26]   REACTIONS OF THE HNS+ IONS (N=O TO 3) WITH SEVERAL MOLECULAR GASES AT THERMAL ENERGIES [J].
SMITH, D ;
ADAMS, NG ;
LINDINGER, W .
JOURNAL OF CHEMICAL PHYSICS, 1981, 75 (07) :3365-3370
[27]  
SPEAKMAN J, 1999, EUR WINT C PLASM SPE
[28]  
SRIWANA T, 1999, IN PRESS J VOLCANOL
[29]   NEW ION-OPTICAL DEVICES UTILIZING OSCILLATORY ELECTRIC-FIELDS .1. PRINCIPLE OF OPERATION AND ANALYTICAL THEORY OF MULTIPOLE DEVICES WITH TWO-DIMENSIONAL ELECTRIC-FIELDS [J].
SZABO, I .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 73 (03) :197-235
[30]  
TANNER SD, 1999, EUR WINT C PLASM SPE