Compact tissue oximeter based on dual-wavelength multichannel time-resolved reflectance

被引:52
作者
Cubeddu, R
Pifferi, A
Taroni, P
Torricelli, A
Valentini, G
机构
[1] CNR, Ctr Elettron Quantist & Strumentazione Elettron, I-20133 Milan, Italy
[2] Politecn Milan, Dipartimento Fis, Inst Nazl Fis Materia, I-20133 Milan, Italy
关键词
D O I
10.1364/AO.38.003670
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We developed a compact dual-wavelength multichannel tissue oximeter based on the time-correlated single-photon counting (TCSPC) technique. The light sources are two pulsed diode lasers (output wavelengths of 672 and 818 nm, an average power of 1 mW, a pulse duration of 100 ps, and a pulse-repetition rate as high as 80 MHz). The time-resolved reflectance photons are detected by a multianode photomultiplier, and the output signals are redirected by a router to different memory blocks of the TCSPC personal computer board. The system's accuracy in determining the absorption mu(alpha) and the reduced-scattering mu(s)' coefficients and in reconstructing absorber concentrations in diffusive media was tested on phantoms. Preliminary in vivo tissue-oxygenation measurements were performed on healthy volunteers under different physiological conditions with a minimum acquisition time of 100 ms and an injected power of less than 100 mu W. (C) 1999 Optical Society of America.
引用
收藏
页码:3670 / 3680
页数:11
相关论文
共 38 条
[21]   INFLUENCE OF GLUCOSE-CONCENTRATION ON LIGHT-SCATTERING IN TISSUE-SIMULATING PHANTOMS [J].
KOHL, M ;
COPE, M ;
ESSENPREIS, M ;
BOCKER, D .
OPTICS LETTERS, 1994, 19 (24) :2170-2172
[22]   Determination of the wavelength dependence of the differential pathlength factor from near-infrared pulse signals [J].
Kohl, M ;
Nolte, C ;
Heekeren, HR ;
Horst, S ;
Scholz, U ;
Obrig, H ;
Villringer, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06) :1771-1782
[23]  
KOHL M, 1988, OSA TRENDS OPTICS PH, V21, P21
[24]   POSSIBLE CORRELATION BETWEEN BLOOD-GLUCOSE CONCENTRATION AND THE REDUCED SCATTERING COEFFICIENT OF TISSUES IN THE NEAR-INFRARED [J].
MAIER, JS ;
WALKER, SA ;
FANTINI, S ;
FRANCESCHINI, MA ;
GRATTON, E .
OPTICS LETTERS, 1994, 19 (24) :2062-2064
[25]   PERFORMANCE COMPARISON OF SEVERAL PUBLISHED TISSUE NEAR-INFRARED SPECTROSCOPY ALGORITHMS [J].
MATCHER, SJ ;
ELWELL, CE ;
COOPER, CE ;
COPE, M ;
DELPY, DT .
ANALYTICAL BIOCHEMISTRY, 1995, 227 (01) :54-68
[26]  
MATCHER SJ, 1993, PHYS MED BIOL, V38, P177
[27]  
MATCHER SJ, 1995, PHYS MED BIOL, V39, P1295
[28]   The oximeter, an instrument for measuring continuously the oxygen saturation of arterial blood in man [J].
Millikan, GA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1942, 13 (10) :434-444
[29]  
Miwa M, 1995, P SOC PHOTO-OPT INS, V2389, P142
[30]   A simple and novel algorithm for time-resolved multiwavelength oximetry [J].
Oda, M ;
Yamashita, Y ;
Nishimura, G ;
Tamura, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (03) :551-562