Comparison of gas chromatography and liquid chromatography mass spectrometric measurements for high accuracy analysis of cholesterol in human serum by isotope dilution mass spectrometry

被引:23
作者
Briche, CSJW [1 ]
Carter, D [1 ]
Webb, KS [1 ]
机构
[1] Lab Govt Chemist, Teddington TW11 0LY, Middx, England
关键词
D O I
10.1002/rcm.646
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cholesterol measurements are of vital clinical importance and reliable reference materials are essential for method validation. Gas chromatography with mass spectrometry (GC/MS) is usually used for the high accuracy analysis of cholesterol by isotope dilution. A certified reference material for cholesterol content in human serum was analysed by isotope dilution utilising GC/MS and liquid chromatography mass spectrometry (LC/MS). The use of LC/MS avoided the need for a derivatisation step. Both LC/MS and GC/MS produced results on the measurement of cholesterol that agreed within 0.5% of the certified value. Moreover, the precision obtained for ratio measurement using both techniques are comparable and lead to relative expanded standard uncertainties (with a coverage factor of 2) varying between 0.2 and 0.5%. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:848 / 853
页数:6
相关论文
共 13 条
[1]  
ABELL LL, 1952, J BIOL CHEM, V195, P357
[2]  
[Anonymous], COMMUNICATION
[3]  
BERNERT JT, 1991, CLIN CHEM, V37, P2053
[4]  
Bievre PD, 1996, ACCREDIT QUAL ASSUR, V1, P3, DOI [10.1007/s007690050026, DOI 10.1007/S007690050026]
[5]   Structured approach to achieving high accuracy measurements with isotope dilution inductively coupled plasma mass spectrometry [J].
Catterick, T ;
Fairman, B ;
Harrington, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) :1009-1013
[6]  
COHEN A, 1980, CLIN CHEM, V26, P854
[7]   DETERMINATION OF SERUM-CHOLESTEROL BY A MODIFICATION OF THE ISOTOPE-DILUTION MASS-SPECTROMETRIC DEFINITIVE METHOD [J].
ELLERBE, P ;
MEISELMAN, S ;
SNIEGOSKI, LT ;
WELCH, MJ ;
WHITE, E .
ANALYTICAL CHEMISTRY, 1989, 61 (15) :1718-1723
[8]   ISOTOPE-DILUTION MASS-SPECTROMETRY OF CHOLESTEROL IN SERUM [J].
FREUDENTHAL, J ;
DERKS, HJGM ;
GRAMBERG, LG ;
TENHOVE, GJ ;
KLAASSEN, R .
BIOMEDICAL MASS SPECTROMETRY, 1981, 8 (01) :5-9
[9]   REDUCTION OF SYSTEMATIC-ERRORS IN QUANTITATIVE-ANALYSIS BY ISOTOPE-DILUTION MASS-SPECTROMETRY (IDMS) - AN ITERATIVE METHOD [J].
HENRION, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (12) :657-658
[10]   Evaluation of contributions to the uncertainty of cholesterol determination in human serum by means of gas chromatography (quadrupole-) mass spectrometry [J].
Henrion, A ;
Dube, G ;
Richter, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (04) :506-508