Implantable cardioverter-defibrillator (ICD) treatment clearly related to design, material, or manufacture were has been in use since 1980 to prevent sudden cardiac death. The high efficacy of the original epicardial systems to terminate tachyarrhythmias was impaired by a substantial perioperative mortality and morbidity, The more ''modern'' transvenous ICD systems have shown a similar high efficacy in terminating ventricular tachyarrhythmias, but with a lower mortality and morbidity. As a background for discussing the impact on complications with present transvenous implantation techniques, the literature was reviewed, A large pacemaker series was used for comparison. Lead complications not reviewed. The present review, covering 107 references over 40 years, gives support for the notion that in transvenously implanted ICD patients the incidence of acute and late complications related to implantation technique is now acceptable. The rate of hematomas, symptomatic thromboembolic complications, peforations, and to a certain degree infections could be improved, however. The major risk factors for implantation-related complications are discussed, and suggestions for future improvement are given.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 105 条
  • [21] CARDIOVERTER-DEFIBRILLATOR SYSTEMS IMPLANTED WITHOUT THORACOTOMY - RADIOGRAPHIC FINDINGS
    CHMIELEWSKI, SR
    ZEGEL, HG
    GOTTLIEB, C
    FREIMAN, DB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (05) : 943 - 946
  • [22] SILICONE POUCH FOR PROTECTION OF AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR LEADS
    CILLEY, JH
    CERNAIANU, AC
    LIBBY, JA
    BALDINO, WA
    DELROSSI, AJ
    [J]. ANNALS OF THORACIC SURGERY, 1991, 51 (03) : 504 - 505
  • [23] SAFETY OF PACEMAKER IMPLANTATION IN PATIENTS WITH TRANSVENOUS (NONTHORACOTOMY) IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    CLEMO, HF
    ELLENBOGEN, KA
    BELZ, MK
    WOOD, MA
    STAMBLER, BS
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (12): : 2285 - 2291
  • [24] THE USE AND INTERACTION OF PERMANENT PACEMAKERS AND THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    COHEN, AI
    WISH, MH
    FLETCHER, RD
    MILLER, FC
    MCCORMICK, D
    SHUCK, J
    SHAPIRA, N
    DELNEGRO, AA
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (06): : 704 - 711
  • [25] INCIDENCE, PRESENTATION, DIAGNOSIS, AND MANAGEMENT OF MALFUNCTIONING IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR RATE-SENSING LEADS
    DAOUD, EG
    KIRSH, MM
    BOLLING, SF
    STRICKBERGER, SA
    MORADY, F
    KOU, WH
    [J]. AMERICAN HEART JOURNAL, 1994, 128 (05) : 892 - 895
  • [26] RADIOLOGIC APPEARANCE OF IMPLANTABLE CARDIAC DEFIBRILLATORS
    EAGAR, G
    GUTIERREZ, FR
    GAMACHE, MC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 25 - 29
  • [27] CLINICAL-EXPERIENCE, COMPLICATIONS, AND SURVIVAL IN 70 PATIENTS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    ECHT, DS
    ARMSTRONG, K
    SCHMIDT, P
    OYER, PE
    STINSON, EB
    WINKLE, RA
    [J]. CIRCULATION, 1985, 71 (02) : 289 - 296
  • [28] COMBINED AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR AND PACEMAKER SYSTEMS - IMPLANTATION TECHNIQUES AND FOLLOW-UP
    EPSTEIN, AE
    KAY, GN
    PLUMB, VJ
    SHEPARD, RB
    KIRKLIN, JK
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (01) : 121 - 131
  • [29] LOW INCIDENCE OF LEAD RELATED COMPLICATIONS ASSOCIATED WITH NONTHORACOTOMY IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR SYSTEMS
    FAHY, GJ
    KLEMAN, JM
    WILKOFF, BL
    MORANT, VA
    PINSKI, SL
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (01): : 172 - 178
  • [30] FINK AS, 1992, PACE, V15, P510