Chemometric evaluation of on-line high-pressure liquid chromatography in mammalian cell cultures: Analysis of amino acids and glucose

被引:38
作者
Larson, TM [1 ]
Gawlitzek, M [1 ]
Evans, H [1 ]
Albers, U [1 ]
Cacia, J [1 ]
机构
[1] Genentech Inc, Mfg Sci, San Francisco, CA 94080 USA
关键词
on-line HPLC; glucose; mammalian cell culture; amino acid metabolism; chemometrics; multiway principal components analysis;
D O I
10.1002/bit.10116
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
An on-line high-pressure liquid chromatography (HPLC) system capable of measuring amino acids and carbohydrates was used to study metabolism in mammalian cell culture systems. The HPLC method utilized anion-exchange chromatography followed by integrated pulsed amperometric detection. The method is capable of measuring 19 amino acids plus glucose with a complete method time of 65 min. In actual cell cultures, the method was shown to be useful for monitoring 17 amino acids plus glucose. The two amino acids that were not accurately monitored were arginine and lysine, possibly due to their elution near the void volume of the column. The HPLC system was used to study variability in metabolism across different cell culture processes, as well as the effect of glucose and glutamine limitation on a single cell culture process. Chemometric analysis was used to draw statistically meaningful conclusions from the highly correlated, multivariate data set that resulted from these experiments. Using chemometrics, variation between processes was linked to differences in uptake rates of seven amino acids. Similarly, lactate concentration, cell density, and aspartate uptake rate were linked to glucose and glutamine limitation. The effect of nutrient limitation on glutamate, alanine, and ammonium was also considered. (C) 2002 John Wiley Sons, Inc.
引用
收藏
页码:553 / 563
页数:11
相关论文
共 22 条
[1]  
CINAR A, 1999, P AM CONTR C SAN DIE
[2]   An integrated amperometry waveform for the direct, sensitive detection of amino acids and amino sugars following anion-exchange chromatography [J].
Clarke, AP ;
Jandik, P ;
Rocklin, RD ;
Liu, Y ;
Avdalovic, N .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2774-2781
[3]  
Cruz HJ, 1999, BIOTECHNOL BIOENG, V66, P104, DOI 10.1002/(SICI)1097-0290(1999)66:2<104::AID-BIT3>3.0.CO
[4]  
2-#
[5]  
Europa AF, 2000, BIOTECHNOL BIOENG, V67, P25, DOI 10.1002/(SICI)1097-0290(20000105)67:1<25::AID-BIT4>3.0.CO
[6]  
2-K
[7]   Human antithrombin III variant production from recombinant BHK cells in a fed-batch culture with on-line control of glucose and glutamine concentrations [J].
Honda, H ;
Lenas, P ;
Watanabe, H ;
Kitade, T ;
Kobayashi, T .
JOURNAL OF FERMENTATION AND BIOENGINEERING, 1998, 85 (05) :532-535
[8]   Analyzing mixtures of amino acids and carbohydrates using bi-modal integrated amperometric detection [J].
Jandik, P ;
Clarke, AP ;
Avdalovic, N ;
Andersen, DC ;
Cacia, J .
JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (01) :193-201
[9]   GROWTH-CHARACTERISTICS IN FED-BATCH CULTURE OF HYBRIDOMA CELLS WITH CONTROL OF GLUCOSE AND GLUTAMINE CONCENTRATIONS [J].
KUROKAWA, H ;
PARK, YS ;
IIJIMA, S ;
KOBAYASHI, T .
BIOTECHNOLOGY AND BIOENGINEERING, 1994, 44 (01) :95-103
[10]   Adaptive fuzzy control of nutrients concentration in fed-batch culture of mammalian cells [J].
Lenas, P ;
Kitade, T ;
Watanabe, H ;
Honda, H ;
Kobayashi, T .
CYTOTECHNOLOGY, 1997, 25 (1-3) :9-15