Investigating the Quantitative Nature of MALDI-TOF MS

被引:129
作者
Szajli, Emilia [1 ]
Feher, Tamas [2 ]
Medzihradszky, Katalin F. [1 ,3 ]
机构
[1] Hungarian Acad Sci, Biol Res Ctr, Prote Res Grp, H-6726 Szeged, Hungary
[2] Hungarian Acad Sci, Inst Biochem, Biol Res Ctr, H-6726 Szeged, Hungary
[3] Univ Calif San Francisco, Dept Pharmaceut Chem, San Francisco, CA 94143 USA
关键词
D O I
10.1074/mcp.M800108-MCP200
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
MALDI-TOF MS has been applied by several groups to relative quantitative measurements. At the same time, the non-quantitative character of this method has been widely reported. We conducted experiments to test the reliability of this technique for quantitation using the statistical method of inverse confidence limit calculation for the first time in this context. The relationship between relative intensities of known amounts of standard peptides and their concentration ratios was investigated. We found that the concentration ratios determined by relative intensity measurements were highly inaccurate and strongly influenced by the molecular milieu of the sample analyzed. Thus, we emphasize the necessity of using the sample itself for calibration. We also performed experiments using an isotope-labeled derivative of the analyte as an internal standard for calibration line generation. As expected, the use of such standard led to a dramatic increase in precision and a less pronounced improvement in accuracy. We recommend performing a similar statistical analysis as a demonstration of reliability for every system where MALDI-TOF MS is used for quantitative measurements. Molecular & Cellular Proteomics 7:2410-2418, 2008.
引用
收藏
页码:2410 / 2418
页数:9
相关论文
共 75 条
[1]   Reproducibility in protein profiling by MALDI-TOF mass spectrometry [J].
Albrethsen, Jakob .
CLINICAL CHEMISTRY, 2007, 53 (05) :852-858
[2]  
Amado FML, 1997, RAPID COMMUN MASS SP, V11, P1347, DOI 10.1002/(SICI)1097-0231(199708)11:12<1347::AID-RCM974>3.0.CO
[3]  
2-8
[4]   Ionic liquids as matrixes for matrix-assisted laser desorption/ionization mass spectrometry [J].
Armstrong, DW ;
Zhang, LK ;
He, LF ;
Gross, ML .
ANALYTICAL CHEMISTRY, 2001, 73 (15) :3679-3686
[5]   Practical quantitative biomedical applications of MALDI-TOF mass spectrometry [J].
Bucknall, M ;
Fung, KYC ;
Duncan, MW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (09) :1015-1027
[6]   Quantitative matrix-assisted laser desorption/ionization mass spectrometry for the determination of enzyme activities [J].
Bungert, D ;
Heinzle, E ;
Tholey, A .
ANALYTICAL BIOCHEMISTRY, 2004, 326 (02) :167-175
[7]  
Burlingame AL, 1998, ANAL CHEM, V70, p647R
[8]  
Canas Benito, 2006, Briefings in Functional Genomics & Proteomics, V4, P295, DOI 10.1093/bfgp/eli002
[9]   Molecular imaging of biological samples: Localization of peptides and proteins using MALDI-TOF MS [J].
Caprioli, RM ;
Farmer, TB ;
Gile, J .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4751-4760
[10]   Matrix-assisted laser desorption/ionization (MALDI) mechanism revisited [J].
Chang, Wei Chao ;
Huang, Ling Chu Lora ;
Wang, Yi-Sheng ;
Peng, Wen-Ping ;
Chang, Huan Cheng ;
Hsu, Nien Yeen ;
Yang, Wen Bin ;
Chen, Chung Hsuan .
ANALYTICA CHIMICA ACTA, 2007, 582 (01) :1-9