Investigating the Quantitative Nature of MALDI-TOF MS

被引:129
作者
Szajli, Emilia [1 ]
Feher, Tamas [2 ]
Medzihradszky, Katalin F. [1 ,3 ]
机构
[1] Hungarian Acad Sci, Biol Res Ctr, Prote Res Grp, H-6726 Szeged, Hungary
[2] Hungarian Acad Sci, Inst Biochem, Biol Res Ctr, H-6726 Szeged, Hungary
[3] Univ Calif San Francisco, Dept Pharmaceut Chem, San Francisco, CA 94143 USA
关键词
D O I
10.1074/mcp.M800108-MCP200
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
MALDI-TOF MS has been applied by several groups to relative quantitative measurements. At the same time, the non-quantitative character of this method has been widely reported. We conducted experiments to test the reliability of this technique for quantitation using the statistical method of inverse confidence limit calculation for the first time in this context. The relationship between relative intensities of known amounts of standard peptides and their concentration ratios was investigated. We found that the concentration ratios determined by relative intensity measurements were highly inaccurate and strongly influenced by the molecular milieu of the sample analyzed. Thus, we emphasize the necessity of using the sample itself for calibration. We also performed experiments using an isotope-labeled derivative of the analyte as an internal standard for calibration line generation. As expected, the use of such standard led to a dramatic increase in precision and a less pronounced improvement in accuracy. We recommend performing a similar statistical analysis as a demonstration of reliability for every system where MALDI-TOF MS is used for quantitative measurements. Molecular & Cellular Proteomics 7:2410-2418, 2008.
引用
收藏
页码:2410 / 2418
页数:9
相关论文
共 75 条
[51]   Sample preparation protocols for MALDI-MS of peptides and oligonucleotides using prestructured sample supports [J].
Nordhoff, E ;
Schürenberg, M ;
Thiele, G ;
Lübbert, C ;
Kloeppel, KD ;
Theiss, D ;
Lehrach, H ;
Gobom, J .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 226 (01) :163-180
[52]   Stable isotope labeling by amino acids in cell culture, SILAC, as a simple and accurate approach to expression proteomics [J].
Ong, SE ;
Blagoev, B ;
Kratchmarova, I ;
Kristensen, DB ;
Steen, H ;
Pandey, A ;
Mann, M .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (05) :376-386
[53]   What do matrix-assisted laser desorption/ionization mass spectra reveal about ionization mechanisms? [J].
Papantonakis, MR ;
Kim, J ;
Hess, WP ;
Haglund, RF .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (06) :639-647
[54]   MALDI-MS-based imaging of small molecules and proteins in tissues [J].
Reyzer, Michelle L. ;
Caprioli, Richard M. .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2007, 11 (01) :29-35
[55]   MALDI mass spectrometry for direct tissue analysis: A new tool for biomarker discovery [J].
Reyzer, ML ;
Caprioli, RM .
JOURNAL OF PROTEOME RESEARCH, 2005, 4 (04) :1138-1142
[56]   Multiplexed protein quantitation in Saccharomyces cerevisiae using amine-reactive isobaric tagging reagents [J].
Ross, PL ;
Huang, YLN ;
Marchese, JN ;
Williamson, B ;
Parker, K ;
Hattan, S ;
Khainovski, N ;
Pillai, S ;
Dey, S ;
Daniels, S ;
Purkayastha, S ;
Juhasz, P ;
Martin, S ;
Bartlet-Jones, M ;
He, F ;
Jacobson, A ;
Pappin, DJ .
MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (12) :1154-1169
[57]   MALDI-TOF mass spectrometry of a combinatorial peptide library:: effect of matrix composition on signal suppression [J].
Schlosser, G ;
Pocsfalvi, G ;
Huszár, E ;
Malorni, A ;
Hudecz, F .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (12) :1590-1594
[58]   i-Tracker:: For quantitative proteomics using iTRAQ™ -: art. no. 145 [J].
Shadforth, IP ;
Dunkley, TPJ ;
Lilley, KS ;
Bessant, C .
BMC GENOMICS, 2005, 6 (1)
[59]   18O Labeling:: a tool for proteomics [J].
Stewart, II ;
Thomson, T ;
Figeys, D .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (24) :2456-2465
[60]   A quantitative analysis of serum sulfatide by matrix-assisted laser desorption ionization time-of-flight mass spectrometry with delayed ion extraction [J].
Sugiyama, E ;
Hara, A ;
Uemura, K .
ANALYTICAL BIOCHEMISTRY, 1999, 274 (01) :90-97