Extraction of viral nucleic acids: Comparison of five automated nucleic acid extraction platforms

被引:45
作者
Verheyen, Jens [1 ]
Kaiser, Rolf [1 ]
Bozic, Michael [2 ]
Timmen-Wego, Monika [1 ]
Maier, Barbara K. [2 ]
Kessler, Harald H. [2 ]
机构
[1] Univ Cologne, Inst Virol, D-50931 Cologne, Germany
[2] Med Univ Graz, IHME, Res Unit Mol Diagnost, Graz, Austria
关键词
Nucleic acids extraction; Automation; Routine viral diagnostics; Norovirus; Cytomegalovirus; CYTOMEGALOVIRUS-INFECTION; DNA EXTRACTION; PERIPHERAL-BLOOD; BONE-MARROW; DIAGNOSIS; DISEASE; TESTS; VERIFICATION; QUANTITATION; VALIDATION;
D O I
10.1016/j.jcv.2012.03.008
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Nucleic acid extraction has a major impact on the reliability of results in routine molecular diagnostics. Optimal isolation of nucleic acids and removal of inhibitors are essential. Objectives: This study compares five different automated extraction platforms for the extraction of norovirus RNA from stool and cytomegalovirus (CMV) DNA from plasma samples. Study design: Norovirus positive stool samples and CMV positive plasma samples were aliquoted and analyzed using five different automated platforms (easyMAG, bioMerieux; m2000sp, Abbott; MagNA Pure LC 2.0, Roche; QiaSymphony, Qiagen; sample preparation module of the VERSANT kPCR Molecular System, Siemens). Similar sample input and output volumes, the identical real-time PCR cycler, and the identical assays for amplification and detection for norovirus RNA and CMV DNA, respectively, were chosen. Results: Of 39 stool samples, 36 tested positive for norovirus RNA with all extraction platforms. The three discrepant samples showed inhibition after extraction with at least one platform. Only with the VERSANT platform all samples tested positive for both the target RNA and the internal controls. Of 42 plasma samples, 27 gave quantifiable results for CMV DNA with all extraction platforms. There was significant variance between viral concentrations when different extraction platforms were compared. The majority of the 15 discrepant samples showed low viral concentrations. The internal control of the CMV assay gave positive results for all samples tested below the limit of quantification. Conclusions: The five automated extraction platforms yielded comparable results. However, the extraction performance was found to be impaired by inhibitory substances in stool samples. (C) 2012 Elsevier B. V. All rights reserved.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 28 条
[21]   Verification and validation of diagnostic laboratory tests in clinical virology [J].
Rabenau, Holger F. ;
Kessler, Harald H. ;
Kortenbusch, Marhild ;
Steinhorst, Andreas ;
Raggam, Reinhard B. ;
Berger, Annemarie .
JOURNAL OF CLINICAL VIROLOGY, 2007, 40 (02) :93-98
[22]   Prenatal diagnosis of congenital human cytomegalovirus infection in amniotic fluid by nucleic acid sequence-based amplification assay [J].
Revello, MG ;
Lilleri, D ;
Zavattoni, M ;
Furione, M ;
Middeldorp, J ;
Gerna, G .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (04) :1772-1774
[23]   Active CMV disease does not always correlate with viral load detection [J].
Ruell, J. ;
Barnes, C. ;
Mutton, K. ;
Foulkes, B. ;
Chang, J. ;
Cavet, J. ;
Guiver, M. ;
Menasce, L. ;
Dougal, M. ;
Chopra, R. .
BONE MARROW TRANSPLANTATION, 2007, 40 (01) :55-61
[24]   Comparative evaluation of in-house manual, and commercial semi-automated and automated DNA extraction platforms in the sample preparation of human stool specimens for a Salmonella enterica 5'-nuclease assay [J].
Schlaurman, Tim ;
de Boer, Richard ;
Patty, Rachel ;
Kooistra-Smid, Mirjarn ;
van Zwet, Anton .
JOURNAL OF MICROBIOLOGICAL METHODS, 2007, 71 (03) :238-245
[25]   DNA, RNA, and Protein Extraction: The Past and The Present [J].
Tan, Siun Chee ;
Yiap, Beow Chin .
JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY, 2009,
[26]   Molecular epidemiology of norovirus outbreaks in Norway during 2000 to 2005 and comparison of four norovirus real-time reverse transcriptase PCR assays [J].
Vainio, Kirsti ;
Myrmel, Mette .
JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (10) :3695-3702
[27]   A comparative evaluation of the sensitivity of two automated and two manual nucleic acid extraction methods for the detection of norovirus by RT-PCR [J].
Witlox, K. J. ;
Nguyen, T. N. ;
Bruggink, L. D. ;
Catton, M. G. ;
Marshall, J. A. .
JOURNAL OF VIROLOGICAL METHODS, 2008, 150 (1-2) :70-72
[28]   Comparison of commercial systems for extraction of nucleic acids from DNA/RNA respiratory pathogens [J].
Yang, Genyan ;
Erdman, Dean E. ;
Kodani, Maja ;
Kools, John ;
Bowen, Michael D. ;
Fields, Barry S. .
JOURNAL OF VIROLOGICAL METHODS, 2011, 171 (01) :195-199