Clutter filter design for ultrasound color flow imaging

被引:210
作者
Bjærum, S [1 ]
Torp, H
Kirstoffersen, K
机构
[1] GE Vingmed Ultrasound, Horten, Norway
[2] Norwegian Univ Sci & Technol, Dept Physiol & Biomed Engn, N-7034 Trondheim, Norway
关键词
D O I
10.1109/58.985705
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
For ultrasound color flow images with high quality, it is important to suppress the clutter signals originating from stationary and slowly moving tissue sufficiently. Without sufficient clutter rejection, low velocity blood flow cannot be measured, and estimates of higher velocities will have a large bias. The small number of samples available (8 to 16) makes clutter filtering in color flow imaging a challenging problem. In this paper, we review and analyze three classes of filters: finite impulse response (FIR), infinite impulse response (IIR), and regression filters. The quality of the filters was assessed based on the frequency response, as well as on the bias and variance of a mean blood velocity estimator using an autocorrelation technique. For FIR filters, the frequency response was improved by allowing a non-linear phase response. By estimating the mean blood flow velocity from two vectors filtered in the forward and backward direction, respectively, the standard deviation was significantly lower with a minimum phase filter than with a linear phase filter. For IIR filters applied to short signals, the transient part of the output signal is important. We analyzed zero, step, and projection initialization, and found that projection initialization gave the best filters. For regression filters, polynomial basis functions provide effective clutter suppression. The best filters from each of the three classes gave comparable bias and variance of the mean blood velocity estimates. However, polynomial regression filters and projection-initialized IIR filters had a slightly better frequency response than could be obtained with FIR filters.
引用
收藏
页码:204 / 216
页数:13
相关论文
共 14 条
[1]  
AIDYANATHAN PP, 1993, MULTIRATE SYSTEMS FI
[2]   INITIALIZATION FOR IMPROVED IIR FILTER PERFORMANCE [J].
CHORNOBOY, ES .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1992, 40 (03) :543-550
[3]   INITIALIZATION TECHNIQUE FOR IMPROVED MTI PERFORMANCE IN PHASED-ARRAY RADARS [J].
FLETCHER, RH ;
BURLAGE, DW .
PROCEEDINGS OF THE IEEE, 1972, 60 (12) :1551-1552
[4]   AN EFFICIENT ALGORITHM TO REMOVE LOW-FREQUENCY DOPPLER SIGNALS IN DIGITAL DOPPLER SYSTEMS [J].
HOEKS, APG ;
VANDEVORST, JJW ;
DABEKAUSSEN, A ;
BRANDS, PJ ;
RENEMAN, RS .
ULTRASONIC IMAGING, 1991, 13 (02) :135-144
[5]   ON THE PERFORMANCE OF REGRESSION AND STEP-INITIALIZED IIR CLUTTER FILTERS FOR COLOR DOPPLER SYSTEMS IN DIAGNOSTIC MEDICAL ULTRASOUND [J].
KADI, AP ;
LOUPAS, T .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (05) :927-937
[6]   REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING AN AUTO-CORRELATION TECHNIQUE [J].
KASAI, C ;
NAMEKAWA, K ;
KOYANO, A ;
OMOTO, R .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (03) :458-464
[7]  
Lim J. S., 1988, Advanced Topics in Signal Processing
[8]   ANALYSIS OF TRANSIT-TIME EFFECTS ON DOPPLER FLOW MEASUREMENT [J].
NEWHOUSE, VL ;
BENDICK, PJ ;
VARNER, LW .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1976, 23 (05) :381-387
[9]  
Parks TW, 1987, DIGITAL FILTER DESIG
[10]  
PETERSON RB, 1994 IEEE ULTR S P, V3, P1705