摘要
Recently an in vivo high-resolution backward-mode photoacoustic microscope was developed that shows potential for applications in dermatology and related cancer research. However, the limited depth of focus of the large-numerical-aperture (NA) ultrasonic lens employed in this system causes the image quality to deteriorate significantly in the out-of-focus region. To solve this problem, we devised and explored, for the first time to our knowledge, a virtual-detector-based synthetic-aperture focusing technique, combined with coherence weighting, for photoacoustic microscopy with such a large-NA transducer. Images of phantoms show that the proposed technique improves the -6 dB lateral resolution from 49-379 to 46-53 mu m and increases the signal-to-noise ratio by up to 29 dB, depending on the distance from the ultrasonic focal point. In vivo experiments show that the technique also provides a clearer representation of the vascular distribution in the rat's scalp. (c) 2006 Optical Society of America.
引用
收藏
页码:474 / 476
页数:3
相关论文
共 11 条
[1]   Sensitivity of laser opto-acoustic imaging in detection of small deeply embedded tumors [J].
Esenaliev, RO ;
Karabutov, AA ;
Oraevsky, AA .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) :981-988
[2]   Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study [J].
Esenaliev, RO ;
Larina, IV ;
Larin, KV ;
Deyo, DJ ;
Motamedi, M ;
Prough, DS .
APPLIED OPTICS, 2002, 41 (22) :4722-4731
[3]   Imaging of tumor angiogenesis in rat brains in vivo by photoacoustic tomography [J].
Ku, G ;
Wang, XD ;
Xie, XY ;
Stoica, G ;
Wang, LHV .
APPLIED OPTICS, 2005, 44 (05) :770-775
[4]   Improved synthetic aperture focusing technique with applications in high-frequency ultrasound imaging [J].
Li, ML ;
Guan, WJ ;
Li, PC .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (01) :63-70
[5]   Adaptive imaging using the generalized coherence factor [J].
Li, PC ;
Li, ML .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (02) :128-141
[6]   Optoacoustic imaging with synthetic aperture focusing and coherence weighting [J].
Liao, CK ;
Li, ML ;
Li, PC .
OPTICS LETTERS, 2004, 29 (21) :2506-2508
[7]  
Maslov K, 2005, OPT LETT, V30, P625, DOI 10.1364/OL.30.6.000625
[8]   Combined ultrasound and optoacoustic system for real-time high-contrast vascular imaging in vivo [J].
Niederhauser, JJ ;
Jaeger, M ;
Lemor, R ;
Weber, P ;
Frenz, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (04) :436-440
[9]  
SAVATEEVA EV, 2000, P SOC PHOTO-OPT INS, V3597, P55, DOI DOI 10.1117/12.386341
[10]   Photoacoustic measurement of epidermal melanin [J].
Viator, JA ;
Svaasand, LO ;
Aguilar, G ;
Choi, B ;
Nelson, JS .
BIOMEDICAL OPTOACOUSTICS IV, 2003, 4960 :14-20