Criterion and Concurrent Validity of the activPAL™ Professional Physical Activity Monitor in Adolescent Females

被引:86
作者
Dowd, Kieran P. [1 ]
Harrington, Deirdre M. [2 ]
Donnelly, Alan E. [1 ]
机构
[1] Univ Limerick, Dept Phys Educ & Sport Sci, Limerick, Ireland
[2] Pennington Biomed Res Ctr, Baton Rouge, LA USA
来源
PLOS ONE | 2012年 / 7卷 / 10期
关键词
ACCELEROMETER OUTPUT; SEDENTARY BEHAVIOR; UNITED-STATES; CALIBRATION; TIME; VALIDATION; INACTIVITY; ACTIGRAPH; PATTERNS; CHILDREN;
D O I
10.1371/journal.pone.0047633
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: The activPAL has been identified as an accurate and reliable measure of sedentary behaviour. However, only limited information is available on the accuracy of the activPAL activity count function as a measure of physical activity, while no unit calibration of the activPAL has been completed to date. This study aimed to investigate the criterion validity of the activPAL, examine the concurrent validity of the activPAL, and perform and validate a value calibration of the activPAL in an adolescent female population. The performance of the activPAL in estimating posture was also compared with sedentary thresholds used with the ActiGraph accelerometer. Methodologies: Thirty adolescent females (15 developmental; 15 cross-validation) aged 15-18 years performed 5 activities while wearing the activPAL, ActiGraph GT3X, and the Cosmed K4B2. A random coefficient statistics model examined the relationship between metabolic equivalent (MET) values and activPAL counts. Receiver operating characteristic analysis was used to determine activity thresholds and for cross-validation. The random coefficient statistics model showed a concordance correlation coefficient of 0.93 (standard error of the estimate = 1.13). An optimal moderate threshold of 2997 was determined using mixed regression, while an optimal vigorous threshold of 8229 was determined using receiver operating statistics. The activPAL count function demonstrated very high concurrent validity (r = 0.96, p<0.01) with the ActiGraph count function. Levels of agreement for sitting, standing, and stepping between direct observation and the activPAL and ActiGraph were 100%, 98.1%, 99.2% and 100%, 0%, 100%, respectively. Conclusions: These findings suggest that the activPAL is a valid, objective measurement tool that can be used for both the measurement of physical activity and sedentary behaviours in an adolescent female population.
引用
收藏
页数:9
相关论文
共 43 条
[1]  
Barnes J, 2012, APPL PHYSIOL NUTR ME, V37, P540, DOI [10.1139/h2012-024, 10.1139/H2012-024]
[2]   Calibration and Validation of Wearable Monitors [J].
Bassett, David R., Jr. ;
Rowlands, Alex ;
Trost, Stewart G. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 :S32-S38
[3]   Medical Hazards of Prolonged Sitting [J].
Bassett, David R., Jr. ;
Freedson, Patty ;
Kozey, Sarah .
EXERCISE AND SPORT SCIENCES REVIEWS, 2010, 38 (03) :101-102
[4]   Obesity prevalence from a European perspective:: a systematic review [J].
Berghoefer, Anne ;
Pischon, Tobias ;
Reinhold, Thomas ;
Apovian, Caroline M. ;
Sharma, Arya M. ;
Willich, Stefan N. .
BMC PUBLIC HEALTH, 2008, 8 (1)
[5]   Suppression of skeletal muscle lipoprotein lipase activity during physical inactivity: a molecular reason to maintain daily low-intensity activity [J].
Bey, L ;
Hamilton, MT .
JOURNAL OF PHYSIOLOGY-LONDON, 2003, 551 (02) :673-682
[6]   Assessing Physical Activity Using Wearable Monitors: Measures of Physical Activity [J].
Butte, Nancy F. ;
Ekelund, Ulf ;
Westerterp, Klaas R. .
MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2012, 44 :S5-S12
[7]   Compliance with physical activity guidelines in a group of UK-based postal workers using an objective monitoring technique [J].
Chastin, Sebastien F. M. ;
Dall, Philippa M. ;
Tigbe, William W. ;
Grant, Margaret P. ;
Ryan, Cormac G. ;
Rafferty, Danny ;
Granat, Malcolm H. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2009, 106 (06) :893-899
[8]  
Colley R., 2011, HLTH REP, V22, P4
[9]  
Department of Transport, 2009, NAT CYCL POL FRAM
[10]   Validation of the GENEA Accelerometer [J].
Esliger, Dale W. ;
Rowlands, Ann V. ;
Hurst, Tina L. ;
Catt, Michael ;
Murray, Peter ;
Eston, Roger G. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (06) :1085-1093