Determination of nicotine in tobacco by molecularly imprinted solid phase extraction with differential pulsed elution

被引:80
作者
Mullett, WM [1 ]
Lai, EPC
Sellergren, B
机构
[1] Carleton Univ, Ottawa Carleton Chem Inst, Dept Chem, Ottawa, ON K1S 5B6, Canada
[2] Johannes Gutenberg Univ Mainz, Dept Inorgan Chem & Analyt Chem, D-55099 Mainz, Germany
来源
ANALYTICAL COMMUNICATIONS | 1999年 / 36卷 / 06期
关键词
D O I
10.1039/a902509j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A molecularly imprinted solid phase extraction-differential pulsed elution (MISPE-DPE) method has been developed for the determination of nicotine in tobacco. Nicotine and a trace alkaloid myosmine were able to bind to the molecularly imprinted polymer (MIP) packed in a micro-column when acetonitrile was used as the mobile phase. However, over 95% of the bound myosmine could be desorbed and washed away by a 20 mu l pulse of methanol, compared to only 43% of the bound nicotine. The remaining quantity of bound nicotine was desorbed by a 20 mu l pulse of 1% trifluoroacetic acid in water, for direct UV detection at 254 mm. This MISPE-DPE method provided inherent selectivity for nicotine that allowed both a shorter analysis time (3 min) and a lower analysis cost than liquid chromatographic methods. A detection limit of 1.8 mu g ml(-1) and a linear dynamic range up to 1000 mu g ml(-1) were obtained. Preconcentration of 845 mu l of a 10 ng ml(-1) nicotine standard solution produced a detectable peak signal. These analytical figures of merit are superior to those reported previously for several nicotine-MIP-based methods.
引用
收藏
页码:217 / 220
页数:4
相关论文
共 19 条
[1]  
Andersson HS, 1996, J MOL RECOGNIT, V9, P675, DOI 10.1002/(SICI)1099-1352(199634/12)9:5/6<675::AID-JMR320>3.0.CO
[2]  
2-C
[3]   Determination of nicotine in water by gradient ion chromatography [J].
Ayers, GP ;
Selleck, PW ;
Gillett, RW ;
Keywood, MD .
JOURNAL OF CHROMATOGRAPHY A, 1998, 824 (02) :241-245
[4]   Liquid chromatographic method for the determination of nicotine in pharmaceutical formulations [J].
Dash, AK ;
Wong, ST .
JOURNAL OF CHROMATOGRAPHY A, 1996, 749 (1-2) :81-85
[5]  
Fukumoto M, 1997, VET HUM TOXICOL, V39, P225
[6]   Determination of nicotine by reagent-injection flow injection photometric method [J].
Liu, JF ;
Feng, YD .
TALANTA, 1998, 47 (04) :833-840
[7]   Application of high-performance capillary electrophoresis to the quantitative analysis of nicotine and profiling of other alkaloids in ATF-regulated tobacco products [J].
Lu, GH ;
Ralapati, S .
ELECTROPHORESIS, 1998, 19 (01) :19-26
[8]   2-(trifluoromethyl)acrylic acid: A novel functional monomer in non-covalent molecular imprinting [J].
Matsui, J ;
DoblhoffDier, O ;
Takeuchi, T .
ANALYTICA CHIMICA ACTA, 1997, 343 (1-2) :1-4
[9]   A molecularly imprinted polymer rod as nicotine selective affinity media prepared with 2-(trifluoromethyl)acrylic acid [J].
Matsui, J ;
Takeuchi, T .
ANALYTICAL COMMUNICATIONS, 1997, 34 (07) :199-200
[10]  
Matsui J, 1996, ANAL LETT, V29, P2071