Complications associated with pectoral implantation of cardioverter defibrillators

被引:46
作者
Gold, MR [1 ]
Peters, RW [1 ]
Johnson, JW [1 ]
Shorofsky, SR [1 ]
机构
[1] MEDTRONIC INC,MINNEAPOLIS,MN
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1997年 / 20卷 / 01期
关键词
implantable cardioverter defibrillator; pectoral pulse generators; lead complications;
D O I
10.1111/j.1540-8159.1997.tb04844.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pectoral placement of ICD pulse generators is now routine after downsizing of these devices. However, the safety of this approach is not well documented. The aim of this study was to evaluate complications in a large cohort of patients undergoing initial pectoral ICD implantation. The subjects for this study were 1,000 consecutive patients receiving a Medtronic Jewel ICD at 93 centers worldwide. Cumulative follow-up for all patients was 634 patient-years, with 64.9% of patients followed for 6 months or longer. The complications evaluated were erosion, pocket hematoma, seroma, wound infection, dehiscence, device migration, lead fracture, and dislodgment. In this series, 1.8% of patients experienced a pocket complication with only 3 (0.3%) erosions and 2 (0.2%) infections. Lead complications were observed in 2.1% of subjects, most commonly early dislodgment of the RV lead. We conclude that pectoral implantation of a downsized ICD system can be performed with a low rate of complications. However, careful attention to anchoring techniques and close early monitoring is important given the 1.7% rate of lead dislodgment that occurred primarily during the first month following implantation.
引用
收藏
页码:208 / 211
页数:4
相关论文
共 20 条
  • [1] A SIMPLIFIED, SINGLE-LEAD UNIPOLAR TRANSVENOUS CARDIOVERSION-DEFIBRILLATION SYSTEM
    BARDY, GH
    JOHNSON, G
    POOLE, JE
    DOLACK, GL
    KUDENCHUK, PJ
    KELSO, D
    MITCHELL, R
    MEHRA, R
    HOFER, B
    [J]. CIRCULATION, 1993, 88 (02) : 543 - 547
  • [2] IMPLANTABLE TRANSVENOUS CARDIOVERTER-DEFIBRILLATORS
    BARDY, GH
    HOFER, B
    JOHNSON, G
    KUDENCHUK, PJ
    POOLE, JE
    DOLACK, GL
    GLEVA, M
    MITCHELL, R
    KELSO, D
    [J]. CIRCULATION, 1993, 87 (04) : 1152 - 1168
  • [3] TECHNIQUE FOR IMPLANTATION OF CARDIOVERTER-DEFIBRILLATORS IN THE SUBPECTORAL POSITION
    FOSTER, AH
    [J]. ANNALS OF THORACIC SURGERY, 1995, 59 (03) : 764 - 767
  • [4] Transvenous defibrillation lead systems
    Gold, MR
    Shorofsky, SR
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (06) : 570 - 580
  • [5] GOLD MR, IN PRESS AM J CARDIO
  • [6] GROGLER FM, 1975, J THORAC CARDIOV SUR, V69, P895
  • [7] SINGLE-INCISION IMPLANTATION OF CARDIOVERTER-DEFIBRILLATORS USING NONTHORACOTOMY LEAD SYSTEMS
    HAMMEL, D
    BLOCK, M
    GEIGER, A
    BOCKER, D
    STADLBAUER, T
    BREITHARDT, G
    SCHELD, HH
    [J]. ANNALS OF THORACIC SURGERY, 1994, 58 (06) : 1614 - 1616
  • [8] CLINICAL-RESULTS WITH NONTHORACOTOMY ICD SYSTEMS
    HAUSER, RG
    KURSCHINSKI, DT
    MCVEIGH, K
    THOMAS, A
    MOWER, MM
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (01): : 141 - 148
  • [9] NONTHORACOTOMY-IMPLANTABLE VERSUS THORACOTOMY-IMPLANTABLE DEFIBRILLATORS - INTENTION-TO-TREAT COMPARISON OF CLINICAL OUTCOMES
    KLEMAN, JM
    CASTLE, LW
    KIDWELL, GA
    MALONEY, JD
    MORANT, VA
    TROHMAN, RG
    WILKOFF, BL
    MCCARTHY, PM
    PINSKI, SL
    [J]. CIRCULATION, 1994, 90 (06) : 2833 - 2842
  • [10] ONE-INCISION APPROACH FOR INSERTION OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    MARKEWITZ, A
    KAULBACH, H
    MATTKE, S
    DORWARTH, U
    WEINHOLD, C
    HOFFMANN, E
    STEINBECK, G
    REICHART, B
    [J]. ANNALS OF THORACIC SURGERY, 1994, 58 (06) : 1609 - 1613