Complications associated with pectoral implantation of cardioverter defibrillators

被引:46
作者
Gold, MR [1 ]
Peters, RW [1 ]
Johnson, JW [1 ]
Shorofsky, SR [1 ]
机构
[1] MEDTRONIC INC,MINNEAPOLIS,MN
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1997年 / 20卷 / 01期
关键词
implantable cardioverter defibrillator; pectoral pulse generators; lead complications;
D O I
10.1111/j.1540-8159.1997.tb04844.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pectoral placement of ICD pulse generators is now routine after downsizing of these devices. However, the safety of this approach is not well documented. The aim of this study was to evaluate complications in a large cohort of patients undergoing initial pectoral ICD implantation. The subjects for this study were 1,000 consecutive patients receiving a Medtronic Jewel ICD at 93 centers worldwide. Cumulative follow-up for all patients was 634 patient-years, with 64.9% of patients followed for 6 months or longer. The complications evaluated were erosion, pocket hematoma, seroma, wound infection, dehiscence, device migration, lead fracture, and dislodgment. In this series, 1.8% of patients experienced a pocket complication with only 3 (0.3%) erosions and 2 (0.2%) infections. Lead complications were observed in 2.1% of subjects, most commonly early dislodgment of the RV lead. We conclude that pectoral implantation of a downsized ICD system can be performed with a low rate of complications. However, careful attention to anchoring techniques and close early monitoring is important given the 1.7% rate of lead dislodgment that occurred primarily during the first month following implantation.
引用
收藏
页码:208 / 211
页数:4
相关论文
共 20 条
  • [11] POOLE JE, 1995, CIRCULATION, V92, P2940
  • [12] DEFIBRILLATION THRESHOLDS AND PERIOPERATIVE MORTALITY ASSOCIATED WITH ENDOCARDIAL AND EPICARDIAL DEFIBRILLATION LEAD SYSTEMS
    SAKSENA, S
    BARDY, G
    BENDITT, D
    CHILSON, D
    CONNOLLY, S
    DORIAN, P
    DOWNAR, E
    DUBUC, M
    ECHT, D
    FISHER, J
    FURMAN, S
    FOGOROS, R
    GULAMHUSEIN, S
    HAFFAJEE, C
    HAMMILL, S
    IRWIN, J
    JOSEPHSON, M
    KLEIN, G
    KRON, J
    LEHMANN, M
    MITCHELL, LB
    PLATIA, E
    PORTERFIELD, J
    SPIELMAN, S
    STEINMAN, R
    SWERDLOW, C
    TANG, A
    WHEELAN, K
    WILBER, D
    ZIPES, D
    ANDRESEN, D
    BLOMSTROMLUNDQVIST, C
    FURLANELLO, F
    JORDAENS, L
    KACET, S
    LUDERITZ, B
    ROSENQVIST, M
    TOUBOUL, P
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (01): : 202 - 207
  • [13] POSTOPERATIVE LEAD-RELATED COMPLICATIONS IN PATIENTS WITH NONTHORACOTOMY DEFIBRILLATION LEAD SYSTEMS
    SCHWARTZMAN, D
    NALLAMOTHU, N
    CALLANS, DJ
    PREMINGER, MW
    GOTTLIEB, CD
    MARCHLINSKI, FE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) : 776 - 786
  • [14] EXPERIENCE WITH 2 DIFFERENT NONTHORACOTOMY SYSTEMS FOR IMPLANTABLE DEFIBRILLATOR IN 170 PATIENTS
    SRA, JS
    NATALE, A
    AXTELL, K
    MAGLIO, C
    JAZAYERI, M
    DESHPANDE, S
    DHALA, A
    BLANCK, Z
    AKHTAR, M
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 1741 - 1750
  • [15] CONSISTENT SUBCUTANEOUS PREPECTORAL IMPLANTATION OF A NEW IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    STANTON, MS
    HAYES, DL
    MUNGER, TM
    TRUSTY, JM
    ESPINOSA, RE
    SHEN, WK
    OSBORN, MJ
    PACKER, DL
    HAMMILL, SC
    [J]. MAYO CLINIC PROCEEDINGS, 1994, 69 (04) : 309 - 314
  • [16] TROUP PJ, 1995, IMPLANTABLE CARDIOVE, P253
  • [17] TRANSVENOUS CARDIOVERTER-DEFIBRILLATORS - COST IMPLICATIONS OF A LESS INVASIVE APPROACH
    VENDITTI, FJ
    OCONNELL, M
    MARTIN, DT
    SHAHIAN, DM
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (04): : 711 - 715
  • [18] WITTE J, 1995, PACE, V18, P1793
  • [19] A PERMANENT TRANSVENOUS LEAD SYSTEM FOR AN IMPLANTABLE PACEMAKER CARDIOVERTER-DEFIBRILLATOR - NONTHORACOTOMY APPROACH TO IMPLANTATION
    YEE, R
    KLEIN, GJ
    LEITCH, JW
    GUIRAUDON, GM
    GUIRAUDON, CM
    JONES, DL
    NORRIS, C
    [J]. CIRCULATION, 1992, 85 (01) : 196 - 204
  • [20] RESULTS OF THE INTERNATIONAL STUDY OF THE IMPLANTABLE PACEMAKER CARDIOVERTER-DEFIBRILLATOR - A COMPARISON OF EPICARDIAL AND ENDOCARDIAL LEAD SYSTEMS
    ZIPES, DP
    ROBERTS, D
    [J]. CIRCULATION, 1995, 92 (01) : 59 - 65