Solid-phase microextraction of N-nitrosamines

被引:115
作者
Grebel, Janel E.
Young, Connie C.
Suffet, I. H.
机构
[1] Univ Calif Los Angeles, Sch Publ Hlth, Environmm Sci & Engn Program, Los Angeles, CA 90095 USA
[2] Los Angeles Cty Sanit Dist, Whittier, CA 90601 USA
关键词
solid-phase microextraction; NDMA; N-nitrosamines; nitrogen chemiluminescence detector; nitrogen-phosphorus detector; wastewater;
D O I
10.1016/j.chroma.2006.03.044
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method was developed for the extraction of seven N-nitrosamine compounds from water by solid-phase microextraction (SPME). The method developed requires a total analysis time of only 1.25 h for both extraction and detection (versus 3-20 h for other isolation techniques). Three gas chromatography (GC) detection systems were tested with the SPME method, nitrogen chemiluminesence, detection (NCD), nitrogen-phosphorus detection (NPD) and chemical ionization mass spectrometry (CI-MS), with method detection limits (MDLs) found in the ng/L range. This method was used to analyze wastewater samples and showed excellent selectivity of extraction. The detection limits of this method for N-nitrosodimethylamine (NDMA) range from 30 to 890 ng/L as a function of detector type. The excellent selectivity of SPME in addition to the fast analysis time would make this method ideal for general surveys, wastewater analysis and laboratory studies (e.g. degradation kinetics or formation potential). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:11 / 18
页数:8
相关论文
共 21 条
[1]   A method for the determination of volatile N-nitrosamines in food by HS-SPME-GC-TEA [J].
Andrade, R ;
Reyes, FGR ;
Rath, S .
FOOD CHEMISTRY, 2005, 91 (01) :173-179
[2]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[3]   SOLID-PHASE MICROEXTRACTION OF NITROGEN-CONTAINING HERBICIDES [J].
BOYDBOLAND, AA ;
PAWLISZYN, JB .
JOURNAL OF CHROMATOGRAPHY A, 1995, 704 (01) :163-172
[4]   Detecting N-nitrosamines in drinking water at nanogram per liter levels using ammonia positive chemical ionization [J].
Charrois, JWA ;
Arend, MW ;
Froese, KL ;
Hrudey, SE .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (18) :4835-4841
[5]  
CHENG RC, 2005, ALTERNATIVE METHODS
[6]   N-Nitrosodimethylamine in Drinking Water Using a Rapid, Solid-Phase Extraction Method [J].
Jenkins, Stephen W. D. ;
Koester, Carolyn J. ;
Taguchi, Vincent Y. ;
Wang, David T. ;
Palmentier, Jean-Paul F. P. ;
Hong, Kim P. .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 1995, 2 (04) :207-210
[7]   Solid-phase microextraction for herbicide determination in environmental samples [J].
Krutz, LJ ;
Senseman, SA ;
Sciumbato, AS .
JOURNAL OF CHROMATOGRAPHY A, 2003, 999 (1-2) :103-121
[8]  
MacDougall D., 1980, ANAL CHEM, V52, P2242, DOI DOI 10.1021/AC50064A004
[9]   N-nitrosodimethylamine (NDMA) as a drinking water contaminant:: A review [J].
Mitch, WA ;
Sharp, JO ;
Trussell, RR ;
Valentine, RL ;
Alvarez-Cohen, L ;
Sedlak, DL .
ENVIRONMENTAL ENGINEERING SCIENCE, 2003, 20 (05) :389-404
[10]   A N-nitrosodimethylamine (NDMA) precursor analysis for chlorination of water and wastewater [J].
Mitch, WA ;
Gerecke, AC ;
Sedlak, DL .
WATER RESEARCH, 2003, 37 (15) :3733-3741