Evaluation of scaffolding effects of five different types of stents by intravascular ultrasound analysis

被引:5
作者
Okabe, T [1 ]
Asakura, Y [1 ]
Ishikawa, S [1 ]
Asakura, K [1 ]
Mitamura, H [1 ]
Ogawa, S [1 ]
机构
[1] Keio Univ, Sch Med, Dept Med, Shinjuku Ku, Tokyo 160, Japan
关键词
D O I
10.1016/S0002-9149(99)00484-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The acute elastic recoil of 5 types of stents immediately after deployment by intravascular ultrasound and quantitative coronary angiography measurements wets analyzed. Successfully implanted stents were: Palmaz-Schatz in 104 lesions, Gianturco-Roubin in 65, Wiktor in 45, gfx in 22, and Multi-Link stents in 22. Before and after stenting, the cross section of the smallest luminal area and vessel area was measured with intravascular ultrasound. The postdilatation balloon area was calculated by quantitative coronary angiography. Percent recoil was calculated as: [1-(preluminal area)/balloon area)] x 100. The ratio of balloon area-to-vessel area was also compared. Although preluminal areas in Gianturco-Roubin and Palmaz-Schatz stents were similar (2.4 +/- 0.1 vs 2.5 +/- 0.1 mm(2), p = NS), postluminal area in the Gianturco-Roubin was significantly smaller than the area in the Palmaz-Schatz (6.3 +/- 0.2 vs 8.3 +/- 0.3 mm(2), p <0.05). Although both the balloon area/vessel area (0.68 +/- 0.05, 0.80 +/- 0.08 vs 0.83 +/- 0.02, p <0.05 ) and the preluminal area (2.1 +/- 0.4, 1.6 +/- 0.2 vs 2.5 +/- 0.1 mm(2), p <0.05) were smaller in gfx and Multi-Link than in the Palmaz-Schatz, postluminal area was comparable to the area in the Palmaz-Schatz (7.8 +/- 0.4, 7.4 +/- 0.4 vs 8.3 +/- 0.3 mm(2), p = NS). Percent recoil in the Gianturco-Roubin was poorest among these 5 groups. More favorable initial gain can be obtained with Palmaz-Schatz, Wiktor, gfx, and Multi-Link stents than with the Gianturco-Roubin stent. (C) 1999 by Excerpta Medico, Inc.
引用
收藏
页码:981 / 986
页数:6
相关论文
共 16 条
[1]   ANGIOGRAPHIC AND CLINICAL OUTCOME OF INTRACORONARY STENTING - IMMEDIATE AND LONG-TERM RESULTS FROM A LARGE SINGLE-CENTER EXPERIENCE [J].
CARROZZA, JP ;
KUNTZ, RE ;
LEVINE, MJ ;
POMERANTZ, RM ;
FISHMAN, RF ;
MANSOUR, M ;
GIBSON, CM ;
SENERCHIA, CC ;
DIVER, DJ ;
SAFIAN, RD ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :328-337
[2]  
CHRISTOPHER JW, 1997, CATHET CARDIOVASC DI, V41, P1
[3]   TRANSLUMINALLY-PLACED COILSPRING ENDARTERIAL TUBE GRAFTS - LONG-TERM PATENCY IN CANINE POPLITEAL ARTERY [J].
DOTTER, CT .
INVESTIGATIVE RADIOLOGY, 1969, 4 (05) :329-+
[4]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[5]   STRENGTH, ELASTICITY, AND PLASTICITY OF EXPANDABLE METAL STENTS - IN-VITRO STUDIES WITH 3 TYPES OF STRESS [J].
FLUECKIGER, F ;
STERNTHAL, H ;
KLEIN, GE ;
ASCHAUER, M ;
SZOLAR, D ;
KLEINHAPPL, G .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (05) :745-750
[6]   MULTICENTER INVESTIGATION OF CORONARY STENTING TO TREAT ACUTE OR THREATENED CLOSURE AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - CLINICAL AND ANGIOGRAPHIC OUTCOMES [J].
GEORGE, BS ;
VOORHEES, WD ;
ROUBIN, GS ;
FEARNOT, NE ;
PINKERTON, CA ;
RAIZNER, AE ;
KING, SB ;
HOLMES, DR ;
TOPOL, EJ ;
KEREIAKES, DJ ;
HARTZLER, GO .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (01) :135-143
[7]   RESULTS OF INTRACORONARY STENTS FOR MANAGEMENT OF CORONARY DISSECTION AFTER BALLOON ANGIOPLASTY [J].
HAUDE, M ;
ERBEL, R ;
STRAUB, U ;
DIETZ, U ;
SCHATZ, R ;
MEYER, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (08) :691-696
[8]   QUANTITATIVE-ANALYSIS OF ELASTIC RECOIL AFTER BALLOON ANGIOPLASTY AND AFTER INTRACORONARY IMPLANTATION OF BALLOON-EXPANDABLE PALMAZ-SCHATZ STENTS [J].
HAUDE, M ;
ERBEL, R ;
ISSA, H ;
MEYER, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) :26-34
[9]   COMPARISON OF MECHANICAL DEFORMATION PROPERTIES OF METALLIC STENTS WITH USE OF STRESS-STRAIN ANALYSIS [J].
LOSSEF, SV ;
LUTZ, RJ ;
MUNDORF, J ;
BARTH, KH .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (02) :341-349
[10]   Intravascular ultrasound predictors of restenosis after percutaneous transcatheter coronary revascularization [J].
Mintz, GS ;
Popma, JJ ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Chuang, YC ;
Griffin, J ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (07) :1678-1687