MR-Based PET Attenuation Correction for PET/MR Imaging

被引:124
作者
Bezrukov, Ilja [1 ,2 ]
Mantlik, Frederic [1 ,2 ]
Schmidt, Holger [1 ,3 ]
Schoelkopf, Bernhard [2 ]
Pichler, Bernd J. [1 ]
机构
[1] Univ Tubingen, Dept Preclin Imaging & Radiopharm, Werner Siemens Fdn, Lab Preclin Imaging & Imaging Technol, D-72076 Tubingen, Germany
[2] Max Planck Inst Intelligent Syst, Dept Empir Inference, Tubingen, Germany
[3] Univ Tubingen, Dept Radiol, D-72076 Tubingen, Germany
关键词
MAGNETIC-RESONANCE; CT IMAGES; BRAIN; SEGMENTATION; ATLAS; RECONSTRUCTION; SYSTEMS;
D O I
10.1053/j.semnuclmed.2012.08.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent progress has allowed hybrid positron emission tomography/magnetic resonance (PET/MR) systems to make the transition from research prototypes to systems with full potential for clinical imaging. Options for directly measuring the attenuation maps, as is possible with PET/computed tomography or PET transmission scans, are not included in PET/MR scanners. New methods to compute attenuation maps from MR data have therefore been developed. Semin Nucl Med 43:45-59 (C) 2013 Published by Elsevier Inc.
引用
收藏
页码:45 / 59
页数:15
相关论文
共 57 条
[31]   Attenuation Correction in MR-PET Scanners with Segmented T1-weighted MR Images [J].
Kops, Elena Rota ;
Wagenknecht, Gudrun ;
Scheins, Juergen ;
Tellmann, Lutz ;
Herzog, Hans .
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, :2530-+
[32]   Scatter Correction Requirements for Likelihood-Based Attenuation Artifact Correction in PET [J].
Laymon, C. M. ;
Bowsher, J. E. ;
Carney, J. P. J. ;
Blodgett, T. M. .
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, :2151-2154
[33]  
Laymon CM, 2004, IEEE NUCL SCI CONF R, P2710
[34]  
LEGOFF R, 1994, P SOC PHOTO-OPT INS, V2167, P725, DOI 10.1117/12.175110
[35]   Attenuation Correction Methods Suitable for Brain Imaging with a PET/MRI Scanner: A Comparison of Tissue Atlas and Template Attenuation Map Approaches [J].
Malone, Ian B. ;
Ansorge, Richard E. ;
Williams, Guy B. ;
Nestor, Peter J. ;
Carpenter, T. Adrian ;
Fryer, Tim D. .
JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (07) :1142-1149
[36]  
Mantlik F, 2010, IEEE MED IM C
[37]   The effect of patient positioning aids on PET quantification in PET/MR imaging [J].
Mantlik, Frederic ;
Hofmann, Matthias ;
Werner, Matthias K. ;
Sauter, Alexander ;
Kupferschlaeger, Juergen ;
Schoelkopf, Bernhard ;
Pichler, Bernd J. ;
Beyer, Thomas .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (05) :920-929
[38]   Variable Lung Density Consideration in Attenuation Correction of Whole-Body PET/MRI [J].
Marshall, Harry R. ;
Prato, Frank S. ;
Deans, Lela ;
Theberge, Jean ;
Thompson, R. Terry ;
Stodilka, Robert Z. .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (06) :977-984
[39]   Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data [J].
Martinez-Moeller, Axel ;
Souvatzoglou, Michael ;
Delso, Gaspar ;
Bundschuh, Ralph A. ;
Chefd'hotel, Christophe ;
Ziegler, Sibylle I. ;
Navab, Nassir ;
Schwaiger, Markus ;
Nekolla, Stephan G. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (04) :520-526
[40]   Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms [J].
Nuyts, J ;
Dupont, P ;
Stroobants, S ;
Benninck, R ;
Mortelmans, L ;
Suetens, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (05) :393-403