The effect of augmentation with resorbable or conventional bone cement on the holding strength for femoral neck fracture devices

被引:60
作者
Eriksson, F [1 ]
Mattsson, P [1 ]
Larsson, S [1 ]
机构
[1] Univ Uppsala Hosp, Dept Orthoped, SE-75185 Uppsala, Sweden
关键词
hip fractures; calcium phosphate cement; norian SRS; polymethylmethacrylate (PMMA); holding power; bone substitute;
D O I
10.1097/00005131-200205000-00003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To compare maximum extraction torque and pull-out load for femoral neck fracture implants inserted with Standard technique or after augmentation with polymethylmethacrylate (PMMA) or calcium phosphate cement (Norian SRS). Design: Biomechanical study using synthetic bone. Intervention: Implants were inserted in foam blocks with three different densities for simulation of normal bone or slight or severe osteoporosis, Tested implants included three screws (AO, Olmed, Hansson), one screw with both threads and a barb (Hybrid), and one pin with a hook (LIH hook-pin). Implants were inserted by standard technique and after augmentation with PMMA or Norian SRS. Main Outcome Measurement: The effect of (a) density of the synthetic bone (low, medium, high), (b) augmentation (none, PMMA, SRS), and (c) type of implant (AO, Olmed, Hansson, Hybrid, LIH) on the maximum extraction torque and pull-out load was determined using a material testing machine. Analysis of variance with Fisher's PLSD post hoc test was used to determine statistical differences. Results: PMMA significantly increased maximum torque and pull-out load for all implants and block densities when compared without cement (p < 0.0001), whereas enhancement With SRS was far less pronounced and most obvious in low density blocks. For screws normally inserted without predrilling (OI-med and Hansson) the use of SRS in high density blocks caused a significant reduction in maximum torque (p < 0.0001) and pull-out load (p < 0.0001). SRS-augmented specimens failed through the cement at the periphery of the threads. whereas PMMA-augmented specimens failed between the cement and the synthetic bone. Conclusion: This study suggests that augmentation with PMMA around femoral neck fracture implants will increase the holding power significantly when compared with standard insertion technique as well as augmentation with calcium phosphate cement. Augmentation with calcium phosphate cement like SRS will increase the holding characteristics mainly in low density bone, whereas in high density bone it might even reduce the maximum torque because of the need for predrilling when using the cement for augmentation.
引用
收藏
页码:302 / 310
页数:9
相关论文
共 27 条
  • [1] Cancellous bone screw thread design and holding power
    Asnis, SE
    Ernberg, JJ
    Bostrom, MPG
    Wright, TM
    Harrington, RM
    Tencer, A
    Peterson, M
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (07) : 462 - 469
  • [2] THE EFFECT OF ADJUNCTIVE METHYLMETHACRYLATE ON FAILURES OF FIXATION AND FUNCTION IN PATIENTS WITH INTERTROCHANTERIC FRACTURES AND OSTEOPOROSIS
    BARTUCCI, EJ
    GONZALEZ, MH
    COOPERMAN, DR
    FREEDBERG, HI
    BARMADA, R
    LAROS, GS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) : 1094 - 1107
  • [3] Percutaneous cannulated screw fixation of femoral neck fractures: The three point principle
    Bout, CA
    Cannegieter, DM
    Juttmann, JW
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (02): : 135 - 139
  • [4] USE OF POLYMETHYLMETHACRYLATE TO ENHANCE SCREW FIXATION IN BONE
    CAMERON, HU
    JACOB, R
    MACNAB, I
    PILLIAR, RM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, 57 (05) : 655 - 656
  • [5] Factors affecting the pullout strength of cancellous bone screws
    Chapman, JR
    Harrington, RM
    Lee, KM
    Anderson, PA
    Tencer, AF
    Kowalski, D
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 391 - 398
  • [6] CHAPMAN JR, 1992, T ORTHOP RES SOC, V17, P406
  • [7] Cement augmentation of intertrochanteric fracture fixation - A cadaver comparison of 2 techniques
    Choueka, J
    Koval, KJ
    Kummer, FJ
    Zuckerman, JD
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (02): : 153 - 157
  • [8] SKELETAL REPAIR BY IN-SITU FORMATION OF THE MINERAL PHASE OF BONE
    CONSTANTZ, BR
    ISON, IC
    FULMER, MT
    POSER, RD
    SMITH, ST
    VANWAGONER, M
    ROSS, J
    GOLDSTEIN, SA
    JUPITER, JB
    ROSENTHAL, DI
    [J]. SCIENCE, 1995, 267 (5205) : 1796 - 1799
  • [9] DeCoster T A, 1990, J Orthop Trauma, V4, P169, DOI 10.1097/00005131-199004020-00012
  • [10] Biomechanical evaluation of calcium phosphate cement-augmented fixation of unstable intertrochanteric fractures
    Elder, S
    Frankenburg, E
    Goulet, J
    Yetkinler, D
    Poser, R
    Goldstein, S
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (06) : 386 - 393