Allergenicity of natural rubber latex gloves

被引:19
作者
Brehler, R [1 ]
Rütter, A [1 ]
Kütting, B [1 ]
机构
[1] UKM Munster, Dept Dermatol, D-48149 Munster, Germany
关键词
immediate-type hypersensitivity; natural rubber latex; gloves; rubber chemicals; prevention;
D O I
10.1034/j.1600-0536.2002.450201.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
The concentrations of proteins, allergens band rubber chemicals are essential parameters of the allergenicity of NRL gloves. To date, a standardized method has been given only for analysis of the protein concentration (DIN EN 455-3), and not for the concentrations of allergens and rubber chemicals. In the present study, we investigated 11 brands of surgical gloves currently available on the German market. Additionally 1 glove, not subjected to final leaching procedures, was added for comparison purposes. Protein concentrations were analysed by different methods in different laboratories. Allergen concentrations were assayed by prick tests in NRL-allergic volunteers and by RAST inhibition methods. Rubber chemicals were analysed by HPTLC and GC. The protein concentrations analysed by the Lowry method in the 2 laboratories gave concordant results, but the correlations between protein and allergen concentrations were low. The protein concentration analysed by HPLC correlated with the allergen concentration, and gave better information on the allergenicity of the gloves. The development of standardized methods for allergen analysis in the assessment routine is necessary, due to significant discrepancy between protein and allergen levels of some gloves. Thiurams were not found in any of the gloves, though carbamates were present in all gloves tested. Our data indicate that washing procedures have little or no effect on the concentration of rubber chemicals.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 11 条
[1]  
ALENIUS H, 1994, ANN ALLERGY, V73, P315
[2]   Protein and allergen content of various natural latex articles [J].
Baur, X ;
Chen, Z ;
RaulfHeimsoth, M ;
Degens, P .
ALLERGY, 1997, 52 (06) :661-664
[3]   American Academy of Dermatology's position paper on latex allergy [J].
Cohen, DE ;
Stewart, L ;
Taylor, J ;
Pratt, M ;
Trotter, K ;
Prawer, S ;
Warshaw, E ;
Rietschel, R ;
Watsky, K ;
Schwarzenberger, K ;
Zug, K ;
Shama, S ;
Godwin, L ;
Kosann, MK ;
Wilson, BA .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1998, 39 (01) :98-106
[4]   Latex allergy: An update [J].
Heese, A ;
Lacher, U ;
Koch, HU ;
Kubosch, J ;
Ghane, Y ;
Peters, KP .
HAUTARZT, 1996, 47 (11) :817-824
[5]  
HEESE A, 1997, ALLERGIEN GEGEN LATE
[6]   RELEASE OF THIURAMS AND CARBAMATES FROM RUBBER GLOVES [J].
KNUDSEN, BB ;
LARSEN, E ;
EGSGAARD, H ;
MENNE, T .
CONTACT DERMATITIS, 1993, 28 (02) :63-69
[7]   Allergologically relevant rubber accelerators in single-use medical gloves [J].
Knudsen, BB ;
Hametner, C ;
Seycek, O ;
Heese, A ;
Koch, HU ;
Peters, KP .
CONTACT DERMATITIS, 2000, 43 (01) :9-15
[9]  
Mahler V, 2000, CLIN EXP ALLERGY, V30, P509
[10]   Measurement of natural rubber latex allergen levels in medical gloves by allergen-specific IgE-ELISA inhibition, RAST inhibition, and skin prick test [J].
Palosuo, T ;
Makinen-Kiljunen, S ;
Alenius, H ;
Reunala, T ;
Yip, E ;
Turjanmaa, K .
ALLERGY, 1998, 53 (01) :59-67