Echocardiographic parameters of the freestyle stentless bioprosthesis in aortic position: The European experience

被引:12
作者
Baur, LHB
Jin, XY
Houdas, Y
Peels, CH
Braun, J
Kappetein, AP
Prat, A
Hazekamp, MG
Van Straten, BHM
Ploeg, A
Sieders, A
Voogd, PJ
Bruschke, AVG
van der Wall, EE
Westaby, S
Huysmans, HA
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, NL-2333 ZA Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Thorac Surg, NL-2333 ZA Leiden, Netherlands
[3] John Radcliffe Hosp, Oxford Heart Ctr, Dept Cardiac Surg, Oxford, England
[4] Hop Cardiol, Dept Cardiol & Thorac Surg, F-59037 Lille, France
[5] Catharina Hosp, Dept Cardiol & Thorac Surg, Eindhoven, Netherlands
关键词
D O I
10.1016/S0894-7317(99)70023-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The objective of this study was to determine normal Doppler and 2-dimensional characteristics of the Freestyle stentless aortic bioprosthesis. The Freestyle aortic bioprosthesis is a new type of aortic xenograft, and experience is limited. We therefore determined the normal range of echocardiographic and Doppler examinations of this valve. Three hundred thirty-nine consecutive patients with a Freestyle aortic bioprosthesis underwent an echocardiographic and Doppler examination according to a common protocol. Investigations were done within 4 weeks after operation, after 3 to 6 months, and after 1, 2, and 3 years. With a valve size from 19 to 27 mm, mean gradients decreased from 7.9 +/- 5.1 mm Hg at discharge to 5.5 +/- 3.8 mm Hg after 3 to 6 months (P < .001). Thereafter, gradients remained stable. Effective orifice area 1 year after implantation was 1.59 +/- 0.58 cm(2) for the 21-mm valves, 1.92 +/- 0.74 cm(2) for the 23-mm valves, 2.03 +/- 0.64 cm(2) for the 25-mm valves, and 2.52 +/- 0.72 cm(2) for the 27-mm valves CP (P < .001). The performance index, the ratio of the measured effective orifice area in the patient divided by the effective orifice area measured in vitro, increased from 67% +/- 20% at discharge to 82% +/- 29% after 1, 2, and 3 years. Performance index was especially very high in the smaller-sized valves. After implantation with the subcoronary technique or root-inclusion technique, small cavities could be seen between the native aortic root and the Freestyle valve. Doppler values were evaluated for the Freestyle stentless porcine bioprostheses in the aortic root. Gradients appear to be close to those measured in native valves over a time period of 3 years.
引用
收藏
页码:729 / 735
页数:7
相关论文
共 28 条
[1]  
ANGELL WW, 1991, J CARDIAC SURG, V6, P595
[2]   Normal echocardiographic characteristics of the Sorin Bicarbon bileaflet prosthetic heart valve in the mitral and aortic positions [J].
Badano, L ;
Mocchegiani, R ;
Bertoli, D ;
DeGaetano, G ;
Carratino, L ;
Pasetti, L ;
Caudullo, M ;
Budini, A ;
Mannello, B ;
Passerone, G .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (06) :632-643
[3]  
BINET JP, 1965, LANCET, V2, P1275
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   LONG-TERM PERFORMANCE OF 580 HOMOGRAFT AND AUTOGRAFT VALVES USED FOR AORTIC-VALVE REPLACEMENT [J].
BODNAR, E ;
WAIN, WH ;
MARTELLI, V ;
ROSS, DN .
THORACIC AND CARDIOVASCULAR SURGEON, 1979, 27 (01) :31-38
[6]  
BURDON TA, 1992, J THORAC CARDIOV SUR, V103, P238
[7]   BIOLOGICAL FACTORS AFFECTING LONG-TERM RESULTS OF VALVULAR HETEROGRAFTS [J].
CARPENTIER, A ;
LEMAIGRE, G ;
ROBERT, L ;
CARPENTIER, S ;
DUBOST, C ;
GERBODE, F .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 58 (04) :467-+
[8]  
DAVID TE, 1990, J THORAC CARDIOV SUR, V99, P113
[9]   Hemodynamic benefits of the Toronto stentless valve [J].
DelRizzo, DF ;
Goldman, BS ;
Christakis, GT ;
David, TE .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (06) :1431-1445
[10]  
DELRIZZO DF, 1994, J CARDIAC SURG, V9, P379