Evaluation of microchip capillary electrophoresis with external contactless conductivity detection for the determination of major inorganic ions and lithium in serum and urine samples

被引:67
作者
Kuban, Pavel [1 ,2 ]
Hauser, Peter C. [1 ]
机构
[1] Univ Basel, Dept Chem, CH-4056 Basel, Switzerland
[2] Acad Sci Czech Republic, Inst Analyt Chem, Brno 60200, Czech Republic
基金
瑞士国家科学基金会;
关键词
D O I
10.1039/b802973c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The determination of inorganic ions in clinical samples in less than 90 seconds was demonstrated for microchip capillary electrophoresis using capacitively coupled contactless conductivity detection ((CD)-D-4). Bare electrophoresis chips were used in combination with external electrodes which were part of the chip holder. In order to achieve the required selectivity and sensitivity, an optimization of the electrode layout was carried out. Limits of detection (LOD) of 1 mu M for K+, 1.5 mu M for Ca2+, 3 mu M for Na+, 1.75 mu M for Mg2+ and 7.5 mu M for Li+ were achieved. The determination of inorganic cations (NH4+, K+, Na+, Ca2+, Mg2+) and anions (Cl-, NO3-, SO42-, phosphate) in blood serum and urine samples was possible in one common electrolyte solution containing 15 mM L-arginine, 10.75 mM maleic acid and 1.5 mM 18-crown-6 at pH 5.90 by simply switching the separation voltage from positive to negative polarity. Lithium, present at significant levels when used for therapeutic purposes, can also be determined in blood serum using a slightly modified background electrolyte solution.
引用
收藏
页码:1829 / 1836
页数:8
相关论文
共 45 条
[1]   Determination of biochemical species on electrophoresis chips with an external contactless conductivity detector [J].
Abad-Villar, EM ;
Kubán, P ;
Hauser, PC .
ELECTROPHORESIS, 2005, 26 (19) :3609-3614
[2]   Detection of human immunoglobulin in microchip and conventional capillary electrophoresis with contactless conductivity measurements [J].
Abad-Villar, EM ;
Tanyanyiwa, J ;
Fernández-Abedul, MT ;
Costa-García, A ;
Hauser, PC .
ANALYTICAL CHEMISTRY, 2004, 76 (05) :1282-1288
[3]   Isotachophoresis and isotachophoresis -: zone electrophoresis separations of inorganic anions present in water samples on a planar chip with column-coupling separation channels and conductivity detection [J].
Bodor, R ;
Madajová, V ;
Kaniansky, D ;
Masár, M ;
Jöhnck, M ;
Stanislawski, B .
JOURNAL OF CHROMATOGRAPHY A, 2001, 916 (1-2) :155-165
[4]   Monitoring environmental pollutants by microchip capillary electrophoresis with electrochemical detection [J].
Chen, G ;
Lin, YH ;
Wang, J .
TALANTA, 2006, 68 (03) :497-503
[5]   Miniaturised isotachophoresis analysis [J].
Chen, L ;
Prest, JE ;
Fielden, PR ;
Goddard, NJ ;
Manz, A ;
Day, PJR .
LAB ON A CHIP, 2006, 6 (04) :474-487
[6]   A thin cover glass chip for contactless conductivity detection in microchip capillary electrophoresis [J].
Chen, Zuanguang ;
Li, Quanwen ;
Li, Oulian ;
Zhou, Xie ;
Lan, You ;
Wei, Yuanfang ;
Mo, Jinyuan .
TALANTA, 2007, 71 (05) :1944-1950
[7]   Improved separation of IA and IIA metal cations in matrices with high sodium concentration by capillary electrophoresis with contactless conductometric detection [J].
da Silva, JAF ;
Ricelli, NL ;
Carvalho, AZ ;
do Lago, CL .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2003, 14 (02) :265-268
[8]   A dry process for production of microfluidic devices based on the lamination of laser-printed polyester films [J].
do Lago, CL ;
da Silva, HDT ;
Neves, CA ;
Brito-Neto, JGA ;
da Silva, JAF .
ANALYTICAL CHEMISTRY, 2003, 75 (15) :3853-3858
[9]   Applications of capillary electrophoresis on microchip [J].
Dolnik, V ;
Liu, SR .
JOURNAL OF SEPARATION SCIENCE, 2005, 28 (15) :1994-2009
[10]   EFFECT OF THE CONCENTRATION OF 18-CROWN-6 ADDED TO THE ELECTROLYTE UPON THE SEPARATION OF AMMONIUM, ALKALI AND ALKALINE-EARTH CATIONS BY CAPILLARY ELECTROPHORESIS [J].
FRANCOIS, C ;
MORIN, P ;
DREUX, M .
JOURNAL OF CHROMATOGRAPHY A, 1995, 706 (1-2) :535-553