A thin cover glass chip for contactless conductivity detection in microchip capillary electrophoresis

被引:49
作者
Chen, Zuanguang [1 ]
Li, Quanwen
Li, Oulian
Zhou, Xie
Lan, You
Wei, Yuanfang
Mo, Jinyuan
机构
[1] Sun Yat Sen Univ, Sch Pharmaceut Sci, Guangzhou 510089, Peoples R China
[2] Sun Yat Sen Univ, Sch Chem & Chem Engineer, Guangzhou 510275, Peoples R China
基金
中国国家自然科学基金;
关键词
micro-total analysis systems (mu-TAS); microchip; contactless conductivity detection; capacitively coupled contactless conductivity detection; high frequency conductivity detection;
D O I
10.1016/j.talanta.2006.08.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfabricated thin glass chip for contactless conductivity detection in chip capillary electrophoresis is presented in this contribution. Injection and separation channels were photolithographed and chemically etched on the surface of substrate glass, which was bonded with a thin cover glass (100 mu m) to construct a new microchip. The chip was placed over an independent contactless electrode plate. Owing to the thinness between channel and electrodes, comparatively low excitation voltage (20-110 V in Vp-p) and frequency (40-65 kHz) were suitable, and favorable signal could be obtained. This microchip capillary electrophoresis device was used in separation and detection of inorganic ions, amino acids and alkaloids in amoorcorn tree bark and golden thread in different buffer solutions. The detection limit of potassium ion was down to 10 mu mol/L. The advantages of this microchip system exist in the relative independence between the microchip and the detection electrodes. It is convenient to the replacement of chip and other operations. Detection in different position of the channel would also be available. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1944 / 1950
页数:7
相关论文
共 30 条
  • [1] Detection of human immunoglobulin in microchip and conventional capillary electrophoresis with contactless conductivity measurements
    Abad-Villar, EM
    Tanyanyiwa, J
    Fernández-Abedul, MT
    Costa-García, A
    Hauser, PC
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (05) : 1282 - 1288
  • [2] Monitoring environmental pollutants by microchip capillary electrophoresis with electrochemical detection
    Chen, G
    Lin, YH
    Wang, J
    [J]. TALANTA, 2006, 68 (03) : 497 - 503
  • [3] Chen ZG, 2002, CHEM J CHINESE U, V23, P801
  • [4] CHEN ZG, 2004, CHEM J CHIN U S, V25, P26
  • [5] Contactless conductivity detection in capillary zone electrophoresis
    Kaniansky, D
    Zelenská, V
    Masár, M
    Iványi, F
    Gazdíková, S
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) : 349 - 359
  • [6] Application of an external contactless conductivity detector for the analysis of beverages by microchip capillary electrophoresis
    Kubán, P
    Hauser, PC
    [J]. ELECTROPHORESIS, 2005, 26 (16) : 3169 - 3178
  • [7] Fundamental aspects of contactless conductivity detection for capillary electrophoresis. Part I: Frequency behavior and cell geometry
    Kuban, P
    Hauser, PC
    [J]. ELECTROPHORESIS, 2004, 25 (20) : 3387 - 3397
  • [8] On-chip contactless four-electrode conductivity detection for capillary electrophoresis devices
    Laugere, F
    Guijt, RM
    Bastemeijer, J
    van der Steen, G
    Berthold, A
    Baltussen, E
    Sarro, P
    van Dedem, GWK
    Vellekoop, M
    Bossche, A
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (02) : 306 - 312
  • [9] Design of an electronic interface for capacitively coupled four-electrode conductivity detection in capillary electrophoresis microchip
    Laugere, F
    Lubking, GW
    Bastemeijer, J
    Vellekoop, MJ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 83 (1-3): : 104 - 108
  • [10] Determination of vitamin C and preservatives in beverages by conventional capillary electrophoresis and microchip electrophoresis with capacitively coupled contactless conductivity detection
    Law, WS
    Kubán, P
    Zha, JH
    Li, SFY
    Hauser, PC
    [J]. ELECTROPHORESIS, 2005, 26 (24) : 4648 - 4655