摘要
Treatment of joint disease that results in limited flexion is often rejected by patients in non-Western cultures whose activities of daily living require a higher range of motion at the hip, knee, or ankle. However, limited information is available about the joint kinematics required for high range of motion activities, such as squatting, kneeling, and sitting cross-legged, making it difficult to design prosthetic implants that will meet the needs of these populations. Therefore, the objective of this work was to generate three-dimensional kinematics at the hip, knee, and ankle joints of Indian subjects while performing activities of daily living. Thirty healthy Indian subjects (average age: 48.2 +/- 7.6 years) were asked to perform six trials of the following activities: squatting, kneeling, and sitting cross-legged. Floating axis angles were calculated at the joints using the kinematic data collected by an electromagnetic motion tracking device with receivers located on the subject's foot, shank, thigh, and sacrum. A mean maximum flexion of 157 degrees +/- 6 degrees at the knee joint was required for squatting with heels up. Mean maximum hip flexion angles reached up to 95 degrees +/- 27 degrees for squatting with heels flat. The high standard deviation associated with this activity underscored the large range in maximum hip flexion angles required by different subjects. Mean ankle range of flexion reached 58 degrees +/- 14 degrees for the sitting cross-legged activity. The ranges of motion required to perform the activities studied are greater than that provided by most currently available joint prostheses, demonstrating the need for high range of motion implant design. (c) 2006 Orthopaedic Research Society.
引用
收藏
页码:770 / 781
页数:12
相关论文
共 33 条
[1]
AHLBERG A, 1988, CLIN ORTHOP RELAT R, P229
[2]
The bisurface total knee replacement: A unique design for flexion - Four-to-nine-year follow-up study [J].
Akagi, M ;
Nakamura, T ;
Matsusue, Y ;
Ueo, T ;
Nishijyo, K ;
Ohnishi, E .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (11) :1626-1633
[3]
Uncemented STAR total ankle prostheses -: Three to eight-year follow-up of fifty-one consecutive ankles [J].
Anderson, T ;
Montgomery, F ;
Carlsson, Å .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (07) :1321-1329
[4]
Knee and hip kinetics during normal stair climbing [J].
Costigan, PA ;
Deluzio, KJ ;
Wyss, UP .
GAIT & POSTURE, 2002, 16 (01) :31-37
[5]
Das De SBP, 1994, J ORTHOP SURG, V2, P33
[6]
Squatting exercises in older adults: Kinematic and kinetic comparisons [J].
Flanagan, S ;
Salem, GJ ;
Wang, MY ;
Sanker, SE ;
Greendale, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (04) :635-643
[7]
A JOINT COORDINATE SYSTEM FOR THE CLINICAL DESCRIPTION OF 3-DIMENSIONAL MOTIONS - APPLICATION TO THE KNEE [J].
GROOD, ES ;
SUNTAY, WJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02) :136-144
[8]
Kinematics of the knee joint in deep flexion: a radiographic assessment [J].
Hefzy, MS ;
Kelly, BP ;
Cooke, TDV .
MEDICAL ENGINEERING & PHYSICS, 1998, 20 (04) :302-307
[9]
Surface movement errors in shank kinematics and knee kinetics during gait [J].
Holden, JP ;
Orsini, JA ;
Siegel, KL ;
Kepple, TM ;
Gerber, LH ;
Stanhope, SJ .
GAIT & POSTURE, 1997, 5 (03) :217-227
[10]
Fluoroscopic analysis of knee arthroplasty kinematics during deep flexion kneeling [J].
Kanekasu, K ;
Banks, SA ;
Honjo, S ;
Nakata, O ;
Kato, H .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :998-1003