Objectives: We sought to compare patellar cartilage volume and thickness measurement between 3D-FLASH and 3D-True fast imaging with steady-state precession (FISP) image data at 3.0 T. Materials and Methods: One knee each of 6 healthy adults was examined by axial magnetic resonance imaging (MRI) performed with a 3D-fast flow angle shot (FLASH) water-excitation sequence and a 3D-TrueFISP water-excitation sequence (spatial resolution 0.31 X 0.31 X 1.5 mm(3)). Patellar cartilage volume and mean/ maximum thickness were calculated. Intraindividual/average reproducibility and interindividual variability were determined from 3 consecutive data sets acquired for each Volunteer and sequence. Results: Patellar cartilage volume and thickness as well as reproducibility was slightly but not significantly lower for the 3DTrueFISP data than for the 3D-FLASH data (volume: 3.4-6.3 mL (3D-FLASH)/3.1-6.0 mL (3D-TrueFISP), average reproducibility 1.8% (3D-FLASH)/4.4% (3D-TrueFISP); mean thickness: 2.1-2.8 mm (3D-FLASH)/1.9-2.6 mm (3D-TrueFISP), average reproducibility 2.8% (3D-FLASH)/3.8% (3D-TrueFISP); maximum thickness: 4.7-6.6 mm (3D-FLASH)/4.5-6.2 mm (31)-TrueFISP), average reproducibility 2.6% (3D-FLASH)/4.1% (3D-TrueFISP)). Interindividual variability was comparable for both sequence techniques. Conclusion: At 3.0 T, the 3D-FLASH sequence showed tendency to be slightly superior to the 3D-TrueFISP sequence considering robust and valid assessment of quantitative cartilage parameters in young healthy adults, although there was found no significant statistical difference between both imaging techniques. However, in patients suffering from osteoarthritis (OA), the 3D-TrueFISP sequence might prove advantageous for monitoring of disease progression and evaluation of therapy success, particularly because the substantially higher signal to noise ratio/contrast to noise ratio values might allow for higher spatial resolution and hence for improvement of the accuracy of segmentation process especially at the articular surface.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 32 条
[1]
Baker CL, 2005, ORTHOPEDICS, V28, pS227
[2]
Chalkias SM, 1994, EUR RADIOL, V4, P353
[3]
Comparison and reproducibility of fast and conventional spoiled gradient-echo magnetic resonance sequences in the determination of knee cartilage volume [J].
Cicuttini, FM ;
Forbes, A ;
Asbeutah, A ;
Morris, K ;
Stuckey, S .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (04) :580-584
[4]
Cicuttini FM, 2002, J RHEUMATOL, V29, P2615
[5]
MR imaging of articular cartilage [J].
Disler, DG ;
Recht, MP ;
McCauley, TR .
SKELETAL RADIOLOGY, 2000, 29 (07) :367-377
[6]
Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: Comparison with standard MR imaging and arthroscopy [J].
Disler, DG ;
McCauley, TR ;
Kelman, CG ;
Fuchs, MD ;
Ratner, LM ;
Wirth, CR ;
Hospodar, PP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) :127-132
[7]
Eckstein F, 1998, CLIN ORTHOP RELAT R, P137
[8]
Eckstein F, 2004, METH MOLEC MED, V101, P191
[9]
In vivo cartilage deformation after different types of activity and its dependence on physical training status [J].
Eckstein, F ;
Lemberger, B ;
Gratzke, C ;
Hudelmaier, M ;
Glaser, C ;
Englmeier, KH ;
Reiser, M .
ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 (02) :291-295
[10]
Interindividual variability and correlation among morphological parameters of knee joint cartilage plates: analysis with three-dimensional MR imaging [J].
Eckstein, F ;
Winzheimer, M ;
Hohe, J ;
Englmeier, KH ;
Reiser, M .
OSTEOARTHRITIS AND CARTILAGE, 2001, 9 (02) :101-111