Background: Twenty-four-hour pH monitoring is an investigation technique that can give both false-positive and false-negative results. depending on patient factors such as diet and different activities. The aim was to study the reproducibility of 24-h oesophageal pH monitoring under as standardized conditions as possible in patients with symptoms of gastro-oesophageal reflux disease. Methods: Antimony pH electrodes were used in 22 adult patients who were investigated twice, 6 weeks apart, under identical conditions. They were hospitalized and were served a standardized diet which had been tested to contain no lower than pH 5.0. Neither coffee nor smoking was allowed. The patients had to refrain from proton-pump inhibitors for 10 days and H-2 blockers for 2 days prior to the investigation. The paired t test was used. Results: There was no significant difference in total reflux time, upright or supine reflux time, or longest reflux periods between the two test occasions. However. there were discordant results in six patients who had normal total reflux time on one test occasion but pathological results on the other. Conclusion: Since the biological variability of gastro-oesophageal reflux is not negligible from time to time, a normal 24-h oesophageal pH test should be assessed with caution.
引用
收藏
页码:6 / 8
页数:3
相关论文
共 12 条
[1]  
DEMEESTER TR, 1980, J THORAC CARDIOV SUR, V79, P656
[2]   Effect of ambulatory 24-hour esophageal pH monitoring on reflux-provoking activities [J].
Fass, R ;
Hell, R ;
Sampliner, RE ;
Pulliam, G ;
Graver, E ;
Hartz, V ;
Johnson, C ;
Jaffe, P .
DIGESTIVE DISEASES AND SCIENCES, 1999, 44 (11) :2263-2269
[3]   24-HOUR ESOPHAGEAL 2-LEVEL PH MONITORING IN HEALTHY-CHILDREN AND ADOLESCENTS [J].
GUSTAFSSON, PM ;
TIBBLING, L .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1988, 23 (01) :91-94
[4]   REPRODUCIBILITY OF 24 HOUR ESOPHAGEAL PH STUDIES IN INFANTS [J].
HAMPTON, FJ ;
MACFADYEN, UM ;
SIMPSON, H .
ARCHIVES OF DISEASE IN CHILDHOOD, 1990, 65 (11) :1249-1254
[5]   ESOPHAGEAL REFLUX TESTS, MANOMETRY, ENDOSCOPY, BIOPSY, AND RADIOLOGY IN HEALTHY-SUBJECTS [J].
JOHANSSON, KE ;
BOERYD, B ;
FRANSSON, SG ;
TIBBLING, L .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1986, 21 (04) :399-406
[6]  
JOHNSON LF, 1974, AM J GASTROENTEROL, V62, P325
[7]   RELIABILITY OF 24-HOUR HOME ESOPHAGEAL PH MONITORING IN DIAGNOSIS OF GASTROESOPHAGEAL REFLUX [J].
MATTIOLI, S ;
PILOTTI, V ;
SPANGARO, M ;
GRIGIONI, WF ;
ZANNOLI, R ;
FELICE, V ;
CONCI, A ;
GOZZETTI, G .
DIGESTIVE DISEASES AND SCIENCES, 1989, 34 (01) :71-78
[8]   LIMITATIONS OF 24-HOUR INTRAESOPHAGEAL PH MONITORING IN THE HOSPITAL SETTING [J].
SCHLESINGER, PK ;
DONAHUE, PE ;
SCHMID, B ;
LAYDEN, TJ .
GASTROENTEROLOGY, 1985, 89 (04) :797-804
[9]   ALKALINE ESOPHAGEAL REFLUX - AN ARTIFACT DUE TO OXYGEN CORROSION OF ANTIMONY PH ELECTRODES [J].
SJOBERG, F ;
GUSTAFSSON, U ;
TIBBLING, L .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1992, 27 (12) :1084-1088
[10]   Exclusion of the meal period improves the clinical reliability of esophageal pH monitoring [J].
Ter, RB ;
Johnston, BT ;
Castell, DO .
JOURNAL OF CLINICAL GASTROENTEROLOGY, 1997, 25 (01) :314-316