Simultaneous determination of trace cadmium and arsenic in biological samples by hydride generation-double channel atomic fluorescence spectrometry

被引:93
作者
Lu, YK
Sun, HW
Yuan, CG
Yan, XP
机构
[1] Nankai Univ, Coll Chem, Res Ctr Analyt Sci, Tianjin 300071, Peoples R China
[2] Hebei Univ, Coll Chem & Environm Sci, Baoding 071002, Peoples R China
关键词
D O I
10.1021/ac0156971
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydride generation atomic fluorescence spectrometry (HG-AFS) has been used for determination of hydride-forming elements because of its high sensitivity, simplicity, and low costs, but most of such work has been concentrated on single element analysis, and reports dealing with multielement determination by HG-nondispersive (ND)AFS are rare. In this work, a sensitive HG-NDAFS method was developed for simultaneous determination of trace cadmium and arsenic in biological materials. The conditions for the generation of volatile cadmium and arsenic species from the reaction with KBH4 in aqueous solution were investigated using a double-channel AFS integrated with an intermittent flow reactor. Like thiourea and Co(II), ascorbic acid was found to significantly enhance the generation efficiency of volatile Cd and As species. The interferences of coexisting ions were evaluated. Under optimal conditions, the detection limits for Cd and As were determined to be 10 and 150 ng L-1, respectively. The precision for 11 replicate determinations at the I mug L-1 Cd level and the 10 mug L-1 As level were 3.5 and 2.7% (RSD), respectively. The recoveries of spike analytes in the biological samples studied ranged from 94 to 109%. The proposed method was successfully applied to the simultaneous determination of Cd and As in a variety of biological samples.
引用
收藏
页码:1525 / 1529
页数:5
相关论文
共 15 条
[1]   Use of flow injection cold vapour generation and preconcentration on coated graphite tubes for the determination of cadmium in sea-water by electrothermal atomic absorption spectrometry [J].
BermejoBarrera, P ;
MoredaPineiro, J ;
MoredaPineiro, A ;
BermejoBarrera, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (11) :1081-1086
[2]   GENERATION OF A VOLATILE CADMIUM SPECIES IN AN ORGANIC MEDIUM [J].
CACHO, J ;
BELTRAN, I ;
NERIN, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (07) :661-663
[3]   DETERMINATION OF CADMIUM IN AQUEOUS SAMPLES BY VAPOR GENERATION WITH SODIUM TETRAETHYLBORATE(III) REAGENT [J].
DULIVO, A ;
CHEN, YW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (04) :319-322
[4]   ULTRA-TRACE DETERMINATION OF CADMIUM BY VAPOR GENERATION ATOMIC FLUORESCENCE SPECTROMETRY [J].
EBDON, L ;
GOODALL, P ;
HILL, SJ ;
STOCKWELL, PB ;
THOMPSON, KC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (05) :723-729
[5]   THE DETERMINATION OF ARSENIC AND SELENIUM IN COAL BY CONTINUOUS-FLOW HYDRIDE-GENERATION ATOMIC-ABSORPTION SPECTROMETRY AND ATOMIC FLUORESCENCE SPECTROMETRY [J].
EBDON, L ;
WILKINSON, JR .
ANALYTICA CHIMICA ACTA, 1987, 194 :177-187
[6]   SIMULTANEOUS DETERMINATION OF ARSENIC(V) AND ARSENIC(III) IN WATER BY INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY USING REDUCTION OF ARSENIC(V) BY L-CYSTEINE AND A SMALL CO-CENTRIC HYDRIDE GENERATOR WITHOUT A GAS-LIQUID SEPARATOR [J].
FENG, YL ;
CAO, JP .
ANALYTICA CHIMICA ACTA, 1994, 293 (1-2) :211-218
[7]  
GOENAGAINFANTE H, 1996, J ANAL ATOM SPECTROM, V11, P571
[8]   Fast automated determination of toxicologically relevant arsenic in urine by flow injection hydride generation atomic absorption spectrometry [J].
Guo, T ;
Baasner, J ;
Tsalev, DL .
ANALYTICA CHIMICA ACTA, 1997, 349 (1-3) :313-318
[9]   USE OF A FLOW-INJECTION HYDRIDE GENERATION TECHNIQUE IN NONDISPERSIVE ATOMIC FLUORESCENCE SPECTROMETRY [J].
GUO, TZ ;
LIU, MZ ;
SCHRADER, W .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) :667-674
[10]   STUDIES ON THE REACTION BETWEEN CADMIUM AND POTASSIUM TETRAHYDROBORATE IN AQUEOUS-SOLUTION AND ITS APPLICATION IN ATOMIC FLUORESCENCE SPECTROMETRY [J].
GUO, XW ;
GUO, XM .
ANALYTICA CHIMICA ACTA, 1995, 310 (02) :377-385