Detection of breast masses in mammograms by density slicing and texture flow-field analysis

被引:162
作者
Mudigonda, NR
Rangayyan, RM [1 ]
Desautels, JE
机构
[1] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB T2N 1N4, Canada
[2] Alberta Canc Board, Calgary, AB T2P 3G9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
breast cancer; breast masses; false-positive analysis; mammography; tumor classification; tumor detection; texture flow-field;
D O I
10.1109/42.974917
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We propose a method for the detection of masses in mammographic images that employs Gaussian smoothing and sub-sampling operations as preprocessing steps. The mass portions are segmented by establishing intensity links from the central portions of masses into the surrounding areas. We introduce methods for analyzing oriented flow-like textural information in mammograms. Features based on flow orientation in adaptive ribbons of pixels across the margins of masses are proposed to classify the regions detected as true mass regions or false-positives (FPs). The methods yielded a mass versus normal tissue classification accuracy represented as an area (A(z)) of 0.87 under the receiver operating characteristics (ROCs) curve with a dataset of 56 images including 30 benign disease, 13 malignant disease, and 13 normal cases selected from the mini Mammographic Image Analysis Society database. A sensitivity of 81% was achieved at 2.2 FPs/image. Malignant tumor versus normal tissue classification resulted in a higher A(x) value of 0.9 under the ROC curve using only the 13 malignant and 13 normal cases with a sensitivity of 85% at 2.45 FPs/image. The mass detection algorithm could detect all the 13 malignant tumors successfully, but achieved a success rate of only 63% (19 / 30) in detecting the benign masses. The mass regions that were successfully segmented were further classified as benign or malignant disease by computing five texture features based on gray-level co-occurrence matrices (GCMS) and using the features in a logistic regression method. The features were computed using adaptive ribbons of pixels across the boundaries of the masses. Benign versus malignant classification using the GCM-based texture features resulted in A(x) = 0.79 with 19 benign and 13 malignant cases.
引用
收藏
页码:1215 / 1227
页数:13
相关论文
共 50 条
[1]   Single and multiscale detection of masses in digital mammograms [J].
Brake, GMT ;
Karssemeijer, N .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (07) :628-639
[2]  
BROWN MB, 1988, BMDP STAT SOFTWARE M
[3]  
BRZAKOVIC D, 1994, STATE ART DIGITAL MA, P103
[4]  
CERNEAZ NJ, 1994, THESIS U OXFORD OXFO
[5]  
Chang C M, 1999, IEEE Trans Inf Technol Biomed, V3, P32, DOI 10.1109/4233.748974
[6]   On digital mammogram segmentation and microcalcification detection using multiresolution wavelet analysis [J].
Chen, CH ;
Lee, GG .
GRAPHICAL MODELS AND IMAGE PROCESSING, 1997, 59 (05) :349-364
[7]  
FERRARI RJ, 2000, P 5 INT WORKSH DIG M, P573
[8]  
Gonzalez R.C., 1992, DIGITAL IMAGE PROCES
[9]  
GROSHONG BR, 1996, P 3 INT WORKSH DIG M, P361
[10]  
GUISSIN R, 1992, 193592 OUEL