Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty - A prospective, randomized, controlled study

被引:206
作者
Parratte, Sebastien [1 ]
Argenson, Jean-Noel A. [1 ]
机构
[1] Univ Aix Marseille 1, Serv Chirurg Orthoped, Hop St Marguerite, F-13009 Marseille, France
关键词
D O I
10.2106/JBJS.F.00529
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Malpositioning of the acetabular component during total hip arthroplasty increases the risk of dislocation, reduces the range of motion, and can be responsible for early wear and loosening. The purpose of this study was to compare computer-assisted with freehand insertion of the acetabular component. Methods: A randomized, controlled, matched prospective study of two groups of thirty patients each was performed. In the first group, cup positioning was assisted by an imageless computer-assisted surgical system based on bone morphing. In the control group, the cup was placed freehand. All of the patients were operated on by the same surgeon through an anterolateral approach. Cup anteversion and abduction angles were measured on three-dimensional computed tomography reconstructions postoperatively for each patient by an independent observer using special cup-evaluation software. Results: There were sixteen men and fourteen women in each group, and the mean body-mass index was approximately 25 in each group. The computer-assisted procedure took a mean of twelve minutes longer than the freehand procedure. Fifty-seven percent (seventeen) of the thirty cups placed freehand and 20% (six) of the thirty in the computer-assisted group were outside of the defined safe zone (outliers). This difference was significant (p = 0.002). There were no differences between the computer-assisted group and the freehand-placement group with regard to the mean abduction and anteversion angles, but there was a significant heterogeneity of variances, with the lowest variations in the computer-assisted group. Conclusions: Use of an imageless navigation system can improve cup positioning in total hip arthroplasty by reducing the percentage of outliers. Level of Evidence: Therapeutic Level II. See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:494 / 499
页数:6
相关论文
共 20 条
[1]
Blendea Sorin, 2005, Comput Aided Surg, V10, P37, DOI 10.3109/10929080500178032
[2]
Assessment of diabetes screening by general practitioners in France: the EPIDIA Study [J].
Cogneau, J ;
Balkau, B ;
Weill, A ;
Liard, F ;
Simon, D .
DIABETIC MEDICINE, 2006, 23 (07) :803-807
[3]
The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[4]
Comparison of a mechanical acetabular alignment guide with computer placement of the socket [J].
DiGioia, AM ;
Jaramaz, B ;
Plakseychuk, AY ;
Moody, JE ;
Nikou, C ;
LaBarca, RS ;
Levison, TJ ;
Picard, F .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :359-364
[5]
Dorr Lawrence D, 2005, Iowa Orthop J, V25, P1
[6]
Eddine TA, 2001, SURG RADIOL ANAT, V23, P105
[7]
Jaramaz B, 1998, CLIN ORTHOP RELAT R, V355, P8
[8]
Factors predisposing to dislocation after primary total hip arthroplasty - A multivariate analysis [J].
Jolles, BM ;
Zangger, P ;
Leyvraz, PF .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :282-288
[9]
Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement [J].
Jolles, BM ;
Genoud, P ;
Hoffmeyer, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :174-179
[10]
Imageless navigation for insertion of the acetabular component in total hip arthroplasty -: Is it as accurate as CT-based navigation? [J].
Kalteis, T ;
Handel, A ;
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02) :163-167