Simultaneous multi-site recordings of neural activity with an inline multi-electrode array and optical measurement in rat hippocampal slices

被引:17
作者
Tominaga, T [1 ]
Tominaga, Y [1 ]
Ichikawa, M [1 ]
机构
[1] RIKEN, BSI, Lab Brain Operat Device, Wako, Saitama 3510198, Japan
来源
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY | 2001年 / 443卷 / 02期
关键词
current source density analysis; Di-4-ANEPPS; electrode; electrophysiology; hippocampus; multi-electrode; optical imaging; voltage-sensitive dye;
D O I
10.1007/s004240100707
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Understanding neuronal network function requires multi-site recording. An optical imaging method using voltage-sensitive dyes (VSD) is one such suitable method. It is also important to complement this technique with methods that measure other physiological parameters of neuronal network activity. We aimed to develop a multi-channel electrode method that would easily permit the simultaneous optical imaging of neural activity in vitro. There are several multi-electrode systems; some of these are commercially available, but they are not easy to use and are also expensive. We developed a novel, less expensive, stainless steel inline electrode array that utilizes the standard etching method of circuit board manufacturing. This method, along with widely available computer drawing software, allowed us to produce electrode arrays with uniform quality in electrical characteristics and shapes. The electrode array was designed so that it could easily substitute for single electrode systems without modifying the conventional set-up used for electrophysiological measurements and optical recordings. Simultaneous measurement of evoked neural activities in area CAI of the rat hippocampal slice with our optical imaging method using the VSD Di-4-ANE-PPS is demonstrated in this paper. The electrode array was also used as a stimulating electrode. and the evoked response was measured by the optical recording method. The results demonstrate the advantages of simultaneous recordings obtained by these complementary multi-site recording methods in vitro.
引用
收藏
页码:317 / 322
页数:6
相关论文
共 15 条
[1]   OPTICAL MEASUREMENT OF MEMBRANE-POTENTIAL [J].
COHEN, LB ;
SALZBERG, BM .
REVIEWS OF PHYSIOLOGY BIOCHEMISTRY AND PHARMACOLOGY, 1978, 83 :35-88
[2]   VISUALIZATION OF THE SPREAD OF ELECTRICAL-ACTIVITY IN RAT HIPPOCAMPAL SLICES BY VOLTAGE-SENSITIVE OPTICAL PROBES [J].
GRINVALD, A ;
MANKER, A ;
SEGAL, M .
JOURNAL OF PHYSIOLOGY-LONDON, 1982, 333 (DEC) :269-291
[3]   OPTICAL IMAGING OF NEURONAL-ACTIVITY [J].
GRINVALD, A ;
FROSTIG, RD ;
LIEKE, E ;
HILDESHEIM, R .
PHYSIOLOGICAL REVIEWS, 1988, 68 (04) :1285-1366
[4]   RECORDING OF SPONTANEOUS ACTIVITY WITH PHOTOETCHED MICROELECTRODE SURFACES FROM MOUSE SPINAL NEURONS IN CULTURE [J].
GROSS, GW ;
WILLIAMS, AN ;
LUCAS, JH .
JOURNAL OF NEUROSCIENCE METHODS, 1982, 5 (1-2) :13-22
[5]  
ICHIKAWA M, 1993, BRAIN MECHANISMS OF PERCEPTION AND MEMORY: FROM NEURON TO BEHAVIOR, P638
[6]  
ICHIKAWA M, 2000, 30 ANN M SOC NEUR NE, P716
[7]   Coupling of organotypic brain slice cultures to silicon-based arrays of electrodes [J].
Jahnsen, H ;
Kristensen, BW ;
Thiébaud, P ;
Noraberg, J ;
Jakobsen, B ;
Bove, M ;
Martinoia, S ;
Koudelka-Hep, M ;
Grattarola, M ;
Zimmer, J .
METHODS-A COMPANION TO METHODS IN ENZYMOLOGY, 1999, 18 (02) :160-172
[8]   A NAPHTHYL ANALOG OF THE AMINOSTYRYL PYRIDINIUM CLASS OF POTENTIOMETRIC MEMBRANE DYES SHOWS CONSISTENT SENSITIVITY IN A VARIETY OF TISSUE, CELL, AND MODEL MEMBRANE PREPARATIONS [J].
LOEW, LM ;
COHEN, LB ;
DIX, J ;
FLUHLER, EN ;
MONTANA, V ;
SALAMA, G ;
WU, JY .
JOURNAL OF MEMBRANE BIOLOGY, 1992, 130 (01) :1-10
[9]   MULTISITE HIPPOCAMPAL SLICE RECORDING AND STIMULATION USING A 32 ELEMENT MICROELECTRODE ARRAY [J].
NOVAK, JL ;
WHEELER, BC .
JOURNAL OF NEUROSCIENCE METHODS, 1988, 23 (02) :149-159
[10]   A new planar multielectrode array for extracellular recording: application to hippocampal acute slice [J].
Oka, H ;
Shimono, K ;
Ogawa, R ;
Sugihara, H ;
Taketani, M .
JOURNAL OF NEUROSCIENCE METHODS, 1999, 93 (01) :61-67