High-performance liquid chromatographic analysis of Peptide T in rabbit plasma with on-line column enrichment

被引:8
作者
Bechgaard, E [1 ]
Bagger, M [1 ]
Larsen, R [1 ]
Nielsen, HW [1 ]
机构
[1] PEPTECH EUROPE AS,DK-3400 HILLEROD,DENMARK
来源
JOURNAL OF CHROMATOGRAPHY B | 1997年 / 693卷 / 01期
关键词
peptide T;
D O I
10.1016/S0378-4347(96)00537-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present paper describes the development of a simple and sensitive analytical method for quantification of Peptide T (PT) in rabbit plasma, using standard analytical equipment and on-line column enrichment, without prior extraction, clean-up or derivatization. The analytical procedure was found to be accurate, precise and linear. The accuracy was 100% (range 97-103%) and the mean precision was 8% (range 3-14%) for all (n=6) concentrations (0, 15, 50, 100 and 200 ng/ml). The total recovery was found to be approximately 80%, and it was found to be dependent upon the injection rate onto the extraction column. The correlation between added and found concentrations was 0.9982, and the limit of detection was estimated to be around 5 ng/ml. The method is therefore found to be suitable for bioavailability studies, involving Peptide T, in rabbits.
引用
收藏
页码:237 / 240
页数:4
相关论文
共 8 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF AN ARGININE-CONTAINING OCTAPEPTIDE ANTAGONIST OF VASOPRESSIN IN HUMAN PLASMA BY MEANS OF A SELECTIVE POSTCOLUMN REACTION WITH FLUORESCENCE DETECTION [J].
BOPPANA, VK ;
RHODES, GR .
JOURNAL OF CHROMATOGRAPHY, 1990, 507 :79-84
[2]   QUANTITATIVE-ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL IONIZATION MASS-SPECTROMETRY - THE DETERMINATION OF THE RENIN INHIBITOR CP-80,794 IN HUMAN SERUM [J].
FOUDA, H ;
NOCERINI, M ;
SCHNEIDER, R ;
GEDUTIS, C .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (02) :164-167
[3]  
JARDIN I, 1990, Journal of Controlled Release, V13, P305, DOI 10.1016/0168-3659(90)90020-T
[4]   DETERMINATION OF A CYCLIC HEPTAPEPTIDE, A NOVEL FIBRINOGEN RECEPTOR ANTAGONIST, IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AUTOMATED PRECOLUMN DERIVATIZATION, COLUMN SWITCHING AND FLUORESCENCE DETECTION [J].
KLINE, WF ;
MATUSZEWSKI, BK ;
HSIEH, JYK .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 578 (01) :31-37
[5]  
PERLMAN R, 1991, PEPTIDE PROTEIN DRUG, P247
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR MELANOTAN-1([NLE(4)-DPHE(7)]ALPHA-MELANOCYTE-STIMULATING HORMONE) IN BIOLOGICAL MATRICES [J].
SURENDRAN, N ;
UGWU, SO ;
STERLING, EJ ;
BLANCHARD, J .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 670 (02) :235-242
[7]   DETERMINATION OF SOME BETA-ENDORPHIN FRAGMENTS IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH LASER-INDUCED FLUORESCENCE DETECTION [J].
VANDENBELD, CMB ;
TJADEN, UR ;
REINHOUD, NJ ;
STEGEHUIS, DS ;
VANDERGREEF, J .
JOURNAL OF CONTROLLED RELEASE, 1990, 13 (2-3) :129-139
[8]   COMBINED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC RADIOIMMUNOASSAY METHODS FOR THE BIOANALYSIS OF PEPTIDES [J].
VENN, RF .