Image characteristics and effective dose estimation of a cone beam CT using a video-fluoroscopic system

被引:9
作者
Endo, M [1 ]
Nishizawa, K
Iwai, K
Matsumoto, M
Yoshida, K
Satoh, K
Matsusita, M
Kusakabe, M
机构
[1] Natl Inst Radiol Sci, Chiba 2638555, Japan
[2] Nihon Univ, Sch Dent, Tokyo 1010062, Japan
[3] Sony Corp, Res Ctr, Tokyo 1410001, Japan
关键词
D O I
10.1109/23.775599
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed a cone beam GT system to acquire volume data of high-contrast objects, such as bone, lung and blood vessels (enhanced by contrast agents), that were amenable to three-dimensional (3D) image processing. An X-ray tube and a large-area detector were mounted on a frame and rotated around an object in 12 seconds. The large-area detector consisted of a fluorescent plate and a CCD (charge coupled device video camera). While the X-ray tube was rotated around the object, X-ray pulses were generated and 360 projected images were collected in a 12-second scan. A 256x256x256 matrix image was reconstructed using a parallel processor with reconstruction time of 6 minutes. Image characteristics, such as spatial resolution, image noise and distortion, were evaluated by phantoms and compared with those of helical CT. Organ or tissue doses by the scan were determined by an in-phantom measurement. The effective dose recommended by ICRP60 was evaluated using the organ or tissue doses. The results showed an isotropic resolving power of less than 1.6 mm and no distortion of the images though they showed larger image noise and effective dose than that of helical CT.
引用
收藏
页码:686 / 690
页数:5
相关论文
共 12 条
[1]  
ANTONUK LE, 1992, MED PHYS, V19, P1445
[2]  
Endo M, 1998, Radiat Med, V16, P7
[3]  
ENDO M, 1992, RADIOLOGY, V185, P271
[4]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[5]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[6]   CARDIAC IMAGING WITH A HIGH-SPEED CINE-CT SCANNER - PRELIMINARY-RESULTS [J].
LIPTON, MJ ;
HIGGINS, CB ;
FARMER, D ;
BOYD, DP .
RADIOLOGY, 1984, 152 (03) :579-582
[7]   Image intensifier-based computed tomography volume scanner for angiography [J].
Ning, R ;
Kruger, RA .
ACADEMIC RADIOLOGY, 1996, 3 (04) :344-350
[8]  
NISHIZAWA K, 1995, NIPPON ACTA RADIOL, V55, P640
[9]  
OKAZAKI T, 1995, P SOC PHOTO-OPT INS, V2432, P456
[10]  
Robb R A, 1982, IEEE Trans Med Imaging, V1, P22, DOI 10.1109/TMI.1982.4307545