Are Bioretention Cells Being Installed Per Design Standards in North Carolina? A Field Study

被引:36
作者
Wardynski, Brad J. [1 ]
Hunt, William F., III [1 ]
机构
[1] N Carolina State Univ, Dept Biol & Agr Engn, Raleigh, NC 27695 USA
来源
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE | 2012年 / 138卷 / 12期
关键词
Bioretention; Rain garden; Best management practice (BMP); Storm water control measure (SCM); Inspection; Construction; Storm water; Survey; Maintenance; POLLUTANT REMOVAL PERFORMANCE; SYSTEMS; HYDROLOGY; RUNOFF; MEDIA;
D O I
10.1061/(ASCE)EE.1943-7870.0000575
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Forty-three bioretention cells (BRCs) throughout North Carolina were assessed for maintenance needs, soil media composition, and as-built surface storage volume to determine whether BRCs are typically constructed per their intended design specifications. Visual inspections identified hydric soils and redoximorphic features (indicators of prolonged anaerobic conditions) and quantified the occurrence of issues requiring maintenance. Particle-size distribution and permeability of soil media were measured at multiple locations within each cell, and topographic surveys were performed to calculate as-built surface storage volumes. Field drawdown tests were used to verify permeability measurements and assess overall BRC function. Of the studied cells, 22% contained redoximorphic features in the upper 30 cm, and 53% were in need of maintenance due to one or more factors. Although 71% of assessed cells failed to meet soil media particle-size distribution specifications, 98% of BRCs contained media with adequate or high permeability. Over half (65%) of cells were undersized vis-a-vis intended design, with 53% exhibiting moderately or severely undersized surface storage capacity. Discrepancies in average ponding depth and incorporation of inspection/maintenance programs significantly influenced the accuracy of as-built BRC storage volume; therefore, it is important for inspectors to verify that the bed elevations of BRCs have been accurately graded. Despite being typically undersized, it was concluded that most observed bioretention cells are meeting the hydrologic goals of North Carolina standards. DOI: 10.1061/(ASCE)EE.1943-7870.0000575. (C) 2012 American Society of Civil Engineers.
引用
收藏
页码:1210 / 1217
页数:8
相关论文
共 31 条
[1]  
[Anonymous], 2006, AGW58805 N CAR COOP
[2]  
[Anonymous], METHODS SOIL ANAL 1
[3]  
[Anonymous], STORMW BEST MAN PRAC
[4]  
[Anonymous], SAS VERS 9 2 COMP PR
[5]  
[Anonymous], AUTOCAD CIV 3D 2010
[6]   Performance Assessment of Rain Gardens1 [J].
Asleson, Brooke C. ;
Nestingen, Rebecca S. ;
Gulliver, John S. ;
Hozalski, Raymond M. ;
Nieber, John L. .
JOURNAL OF THE AMERICAN WATER RESOURCES ASSOCIATION, 2009, 45 (04) :1019-1031
[7]   Underdrain Configuration to Enhance Bioretention Exfiltration to Reduce Pollutant Loads [J].
Brown, R. A. ;
Hunt, W. F. .
JOURNAL OF ENVIRONMENTAL ENGINEERING, 2011, 137 (11) :1082-1091
[8]   Impacts of Media Depth on Effluent Water Quality and Hydrologic Performance of Undersized Bioretention Cells [J].
Brown, Robert A. ;
Hunt, William F., III .
JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 2011, 137 (03) :132-143
[9]   Influence of Planting Soil Mix Characteristics on Bioretention Cell Design and Performance [J].
Carpenter, Donald D. ;
Hallam, Laura .
JOURNAL OF HYDROLOGIC ENGINEERING, 2010, 15 (06) :404-416
[10]   Storm-Water Filter Media Pollutant Retention under Aerobic versus Anaerobic Conditions [J].
Clark, Shirley ;
Pitt, Robert .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2009, 135 (05) :367-371