The precision of radiostereometric measurements.: Manual vs. digital measurements

被引:89
作者
Börlin, N [1 ]
Thien, T
Kärrholm, J
机构
[1] Umea Univ, Dept Comp Sci, S-90187 Umea, Sweden
[2] Katholieke Univ Nijmegen, Biomech Sect, NL-6500 Nijmegen, Netherlands
[3] Sahlgrens Univ Hosp, Dept Orthopaed, S-41345 Gothenburg, Sweden
关键词
radiostereometry; digital radiographs; precision; micromotion; wear;
D O I
10.1016/S0021-9290(01)00162-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The precision of digital vs. manual radiostereometric measurements in total hip arthroplasty was evaluated using repeated stereoradiographic exposures with an interval of 10-15 min, Ten Lubinus SP2 stems cemented into bone specimens and 12 patients with the same stem design were used to evaluate the precision of stem translations and rotations. The precision of translations and rotations of the cup and femoral head penetration was studied in 12 patients with whole polyethylene cups. The use of a measurement method based on digitised radiographs improved the precision for some of the motion parameters, whereas many of them did not change. A corresponding pattern was observed for both the intra- and interobserver error. Of the wear parameters. the most pronounced improvements were the 3D wear and in the proximal-distal direction, although the anterior-posterior precision was also improved. The mean errors of rigid body and elliptic fitting decreased in all evaluations but one, consistent with a more reproducible identification of the markers centres and the edge of the femoral head. Increased precision of radiostereometric measurements may be used to increase the statistical power of future randomised studies and to study new fields in orthopaedics requiring higher precision than has been available with RSA based on manual measurements. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:69 / 79
页数:11
相关论文
共 20 条
[1]
BORLIN N, 1997, P ORS ORTHOPAEDIC RE, P626
[2]
BORLIN N, 1992, THESIS UMEA U
[3]
Regularization tools for training large feed-forward neural networks using automatic differentiation [J].
Eriksson, J ;
Gulliksson, M ;
Lindström, P ;
Wedin, PA .
OPTIMIZATION METHODS & SOFTWARE, 1998, 10 (01) :49-69
[4]
Gonzalez R., 1992, DIGITAL IMAGE PROCES, P583
[5]
GRANLUND GH, 1995, SIGNAL PROCESSING CO, P97
[6]
Karrholm J, 1997, CLIN ORTHOP RELAT R, P94
[7]
MICROMOTION OF FEMORAL STEMS IN TOTAL HIP-ARTHROPLASTY - A RANDOMIZED STUDY OF CEMENTED, HYDROXYAPATITE-COATED, AND POROUS-COATED STEMS WITH ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS [J].
KARRHOLM, J ;
MALCHAU, H ;
SNORRASON, F ;
HERBERTS, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (11) :1692-1705
[8]
ROENTGEN STEREOPHOTOGRAMMETRY - REVIEW OF ORTHOPEDIC APPLICATIONS [J].
KARRHOLM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (04) :491-503
[9]
Fixation and metal release from the Tifit femoral stem prosthesis - 5-year follow-up of 64 cases [J].
Karrholm, J ;
Frech, W ;
Nivbrant, B ;
Malchau, H ;
Snorrason, F ;
Herberts, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (04) :369-378
[10]
Increased migration of the SHP prosthesis -: Radiostereometric comparison with the Lubinus SP2 design in 40 cases [J].
Nivbrant, B ;
Kärrholm, J ;
Söderlund, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (06) :569-577