Increased migration of the SHP prosthesis -: Radiostereometric comparison with the Lubinus SP2 design in 40 cases

被引:33
作者
Nivbrant, B [1 ]
Kärrholm, J
Söderlund, P
机构
[1] No Univ Hosp, Dept Orthoped, SE-90185 Umea, Sweden
[2] Sahlgrens Univ Hosp, Dept Orthoped, S-41345 Gothenburg, Sweden
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1999年 / 70卷 / 06期
关键词
D O I
10.3109/17453679908997844
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
40 patients with primary arthrosis were randomized to receive either a cemented SHP (Scientific Hip Prosthesis) or Lubinus SP2 prosthesis. At 2 years radiostereometric measurements showed increased proximal migration (0.4/0.2 mm; p = 0.02) and more proximal wear (0.3/0.1 mm, p = 0.07) of the SHP socket. The SHP stem also subsided (-0.6/-0.1 mm, p < 0.001) and rotated more into retroversion (2.6/0.3 degrees) than did the SP2 design. This subsidence mainly occurred inside the cement mantle in 17 of 18 cases (13 SHP, 4 SP2), where this type of motion could be measured. The changes in bone mineral density evaluated with DEXA and the clinical results did not differ between the 2 groups. The subsidence of the SHP stem is the most pronounced so far recorded with radiostereometry in stems without a completely polished surface. This subsidence and the rotational instability imply a substantial risk of abrasive wear and increased stresses in the cement mantle.
引用
收藏
页码:569 / 577
页数:9
相关论文
共 33 条
[1]
Cement migration after THR -: A comparison of Charnley Elite and Exeter femoral stems using RSA [J].
Alfaro-Adrián, J ;
Gill, HS ;
Murray, DW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01) :130-134
[2]
INSTABILITY AND WEAR OF TOTAL HIP PROSTHESES DETERMINED WITH ROENTGEN STEREOPHOTOGRAMMETRY [J].
BALDURSSON, H ;
EGUND, N ;
HANSSON, LI ;
SELVIK, G .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1979, 95 (04) :257-263
[3]
IMPROVED CEMENTING TECHNIQUES AND FEMORAL COMPONENT LOOSENING IN YOUNG-PATIENTS WITH HIP-ARTHROPLASTY - A 12-YEAR RADIOGRAPHIC REVIEW [J].
BARRACK, RL ;
MULROY, RD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :385-389
[4]
Porosity reduction in bone cement at the cement-stem interface [J].
Bishop, NE ;
Ferguson, S ;
Tepic, S .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (03) :349-356
[5]
FRACTURE AND LOOSENING OF CHARNLEY FEMORAL STEMS - COMPARISON BETWEEN 1ST-GENERATION AND SUBSEQUENT DESIGNS [J].
DALL, DM ;
LEARMONTH, ID ;
SOLOMON, MI ;
MILES, AW ;
DAVENPORT, JM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :259-265
[6]
Early revision among 12,179 hip prostheses - A comparison of 10 different brands reported to the Norwegian Arthroplasty Register, 1987-1993 [J].
Espehaug, B ;
Havelin, LI ;
Engesaeter, LB ;
Vollset, SE ;
Langeland, N .
ACTA ORTHOPAEDICA SCANDINAVICA, 1995, 66 (06) :487-493
[7]
FOWLER JL, 1988, ORTHOP CLIN N AM, V19, P477
[8]
CHARACTERIZATION OF POLYMETHYLMETHACRYLATE BONE CEMENT [J].
HAAS, SS ;
BRAUER, GM ;
DICKSON, G .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, A 57 (03) :380-391
[9]
HERBERTS P, 1997, CLIN ORTHOP RELAT R, V344, P44
[10]
MATHEMATICAL SHAPE OPTIMIZATION OF HIP-PROSTHESIS DESIGN [J].
HUISKES, R ;
BOEKLAGEN, R .
JOURNAL OF BIOMECHANICS, 1989, 22 (8-9) :793-&