Early revision among 12,179 hip prostheses - A comparison of 10 different brands reported to the Norwegian Arthroplasty Register, 1987-1993

被引:29
作者
Espehaug, B
Havelin, LI
Engesaeter, LB
Vollset, SE
Langeland, N
机构
[1] HAUKELAND UNIV HOSP, DEPT ORTHOPAED & TRAUMATOL, N-5021 BERGEN, NORWAY
[2] BUSKERUD CENT HOSP, DEPT ORTHOPED, N-3004 DRAMMEN, NORWAY
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1995年 / 66卷 / 06期
关键词
D O I
10.3109/17453679509002300
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
On the basis of data from the Norwegian Arthroplasty Register during the period 1987-1993, we have compared times to revision for 10 different cemented total hip prostheses. A total of 11,169 patients, with 12,179 primary total hip replacements (THRs), performed with high viscosity cement for primary arthrosis and followed for a maximum of 6.4 years, were included in this study. The Kaplan-Meier estimate of the overall percentage revised after 5 years was 2.5 (95% Confidence Interval: 2.1-3.0). For the Charnley prosthesis (n 6,694), 2.9% were revised after 5 years (95% CI: 2.3-3.4). Using Cox regression to adjust for gender, age, type of cement and use of systemic antibiotic prophylaxis, the Charnley prosthesis was compared with the 9 other brands. The revision rate for the Spectron/ITH combination (Spectron acetabulum, ITH femur) (n 1,034) was only 0.35 (p 0.04) times that of the Charnley prostheses. The Elite/Charnley combination (Elite acetabulum, Charnley femur) (n 507) and the Muller Type prosthesis (n 116) showed poorer results with failure rates 2.3 (p 0.01) and 2.7 times (p 0.04) that of Charnley, respectively. Although the overall results for cemented THRs in general were good, clinically important differences in revision rates were demonstrated among the cemented prosthesis brands. Our findings underline the need for careful evaluation of different total hip replacements.
引用
收藏
页码:487 / 493
页数:7
相关论文
共 17 条
[1]
AHNFELT L, 1990, ACTA ORTHOP SCAND, V61, P1
[2]
WEAR INDUCED BY MOTION BETWEEN BONE AND TITANIUM OR COBALT-CHROME ALLOYS [J].
BISCHOFF, UW ;
FREEMAN, MAR ;
SMITH, D ;
TUKE, MA ;
GREGSON, PJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05) :713-716
[3]
DIXON WJ, 1992, BMDP STATISTICAL SOF
[4]
CURRENT CONCEPTS IN ORTHOPEDIC BIOMATERIALS AND IMPLANT FIXATION [J].
FRIEDMAN, RJ ;
BLACK, J ;
GALANTE, JO ;
JACOBS, JJ ;
SKINNER, HB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (07) :1086-1109
[5]
EARLY AND LATE LOOSENING OF THE ACETABULAR CUP AFTER LOW-FRICTION ARTHROPLASTY [J].
GARCIACIMBRELO, E ;
MUNUERA, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (08) :1119-1129
[7]
THE NORWEGIAN-ARTHROPLASTY-REGISTER - A SURVEY OF 17,444 HIP REPLACEMENTS 1987-1990 [J].
HAVELIN, LI ;
ESPEHAUG, B ;
VOLLSET, SE ;
ENGESAETER, LB ;
LANGELAND, N .
ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (03) :245-251
[8]
EARLY ASEPTIC LOOSENING OF UNCEMENTED FEMORAL COMPONENTS IN PRIMARY TOTAL HIP-REPLACEMENT - A REVIEW BASED ON THE NORWEGIAN ARTHROPLASTY REGISTER [J].
HAVELIN, LI ;
ESPEHAUG, B ;
VOLLSET, SE ;
ENGESAETER, LB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (01) :11-17
[9]
HAVELIN LI, 1995, IN PRESS J BONE JOIN
[10]
THE DIFFERENCES IN TOXICITY AND RELEASE OF BONE-RESORBING MEDIATORS INDUCED BY TITANIUM AND COBALT-CHROMIUM-ALLOY WEAR PARTICLES [J].
HAYNES, DR ;
ROGERS, SD ;
HAY, S ;
PEARCY, MJ ;
HOWIE, DW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (06) :825-834