Long-term outcomes of ultra-thin porous polyethylene implants used for reconstruction of orbital floor defects

被引:43
作者
Ozturk, S [1 ]
Sengezer, M [1 ]
Isik, S [1 ]
Turegun, M [1 ]
Deveci, M [1 ]
Cil, Y [1 ]
机构
[1] Gulhane Mil Med Acad, Dept Plast & Reconstruct Surg, Ankara, Turkey
关键词
orbital floor defect; reconstruction; medpor; ultra-thin porous polyethylene implant;
D O I
10.1097/01.scs.0000179744.91165.3a
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The objective of this article is to present the long-term outcomes of ultra-thin polyethylene implants used for orbital floor reconstruction in facial trauma patients. Materials and Methods: From 1998 to 2004, 38 patients underwent orbital floor reconstruction with porous polyethylene implants with a mean follow-up of 4 years. A subciliary incision and preexisting facial wounds or scars were used. The boundaries of the maxillofacial injury and the orbital volumes of both orbits were assessed by computed tomography images obtained pre- and postoperatively. In all patients, ultra-thin porous polyethylene implants in various sizes were used to reconstruct the orbital floor defect. Results: None of the patients needed removal of the implants during the follow-up. The volume increase of the traumatized orbits ranged from 0.04 to 6.18 (average 3.12 +/- 1.48) mL compared with the intact orbit (P < 0.01). This difference was not significant postoperatively (P > 0.01). Postoperative ectropion in three cases was corrected under local anesthesia. Persistence of complications were as follows: enophthalmos, 3 in 28; diplopia,1 in 16; dystopia,1 in 4; and infraorbital nerve hypoesthesia, 3 in 31. One patient underwent late enucleation of the globe because of initial penetrating trauma. Conclusions: We recommend the use of ultrathin porous polyethylene implants in the reconstruction of the orbital floor defects in facial trauma patients. The implants are durable in the long-term and mimic the anatomy of the thin orbital floor and avoid the morbidity of autogenous bone grafts.
引用
收藏
页码:973 / 977
页数:5
相关论文
共 22 条
[1]  
BERGHAUS A, 1985, ARCH OTOLARYNGOL, V111, P154
[2]   CORRECTION OF ENOPHTHALMOS WITH POROUS POLYETHYLENE IMPLANTS [J].
BILYK, JR ;
RUBIN, PAD ;
SHORE, JW .
INTERNATIONAL OPHTHALMOLOGY CLINICS, 1992, 32 (03) :151-156
[3]   ORBITAL VOLUME MEASUREMENTS IN ENOPHTHALMOS USING 3-DIMENSIONAL CT IMAGING [J].
BITE, U ;
JACKSON, IT ;
FORBES, GS ;
GEHRING, DG .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1985, 75 (04) :502-507
[4]  
Choi J C, 1995, J Craniomaxillofac Trauma, V1, P42
[5]   Measurement of orbital volume by a 3-dimensional software program:: An experimental study [J].
Deveci, M ;
Öztürk, S ;
Sengezer, M ;
Pabuscu, Y .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2000, 58 (06) :645-648
[6]   Comparison of pre- and postoperative orbital volume using three dimensional CT imaging in zygoma fracture patients [J].
Deveci, M ;
Ozturk, S ;
Sengezer, M ;
Pabuscu, Y .
EUROPEAN JOURNAL OF PLASTIC SURGERY, 2000, 23 (08) :432-437
[7]   COMPLEX NASOETHMOID ORBITAL AND MIDFACIAL FRACTURES - ROLE OF CRANIOFACIAL SURGICAL TECHNIQUES AND IMMEDIATE BONE-GRAFTING [J].
GRUSS, JS .
ANNALS OF PLASTIC SURGERY, 1986, 17 (05) :377-390
[8]   An evaluation of the support provided by common internal orbital reconstruction materials [J].
Haug, RH ;
Nuveen, E ;
Bredbenner, T .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (05) :564-570
[9]   SPLIT CALVARIAL GRAFTS IN MAXILLOFACIAL RECONSTRUCTION [J].
HUNTER, D ;
BAKER, S ;
SOBOL, SM .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1990, 102 (04) :345-350
[10]  
JORDAN DR, 1992, OPHTHALMOLOGY, V99, P1600