Glucose sensor using a microfabricated electrode and electropolymerized bilayer films

被引:68
作者
Yang, H
Chung, TD
Kim, YT
Choi, CA
Jun, CH
Kim, HC
机构
[1] Microsyst Team, Elect & Telecommun Res Inst, Taejon 305600, South Korea
[2] Seoul Natl Univ, Inst Med & Biol Engn, Seoul 110799, South Korea
关键词
glucose sensors; electropolymerized nonconducting film; interference; microfabricated electrode;
D O I
10.1016/S0956-5663(01)00266-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new type miniaturized glucose sensor with good selectivity and stable current response has been developed. The structure consists of a recessed rectangular microfabricated platinum electrode, inner layer of two electropolymerized nonconducting films, and outer bilayer of poly(tetrafluoroethylene) (Teflon) and polyurethane (PU) films. Glucose oxidase (GOx) is entrapped during the electropolymerization of a poly(in-phenylenediamine) (PMPD) film in an acetate buffer (AB) solution, on which a highly interference-resistive PMPD film is deposited in a phosphate buffered saline (PBS) solution. The second PMPD film causes no significant decrease in accessibility of glucose to GOx. The inner layer maintains less than 1% permeability to acetaminophen for 12 days. The fairly adhesive outer layer allows stable current response. Due to high permeability, the information about enzyme activity can be obtained without serious error in spite of outer layer intervening between enzymes and solution. The apparent Michaelis-Menten constant and the maximum steady-state current density were 24 mM and 80 muA cm(-2) respectively. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:251 / 259
页数:9
相关论文
共 51 条
[31]   ELECTROPOLYMERIZED 1,2-DIAMINOBENZENE AS A MEANS TO PREVENT INTERFERENCES AND FOULING AND TO STABILIZE IMMOBILIZED ENZYME IN ELECTROCHEMICAL BIOSENSORS [J].
SASSO, SV ;
PIERCE, RJ ;
WALLA, R ;
YACYNYCH, AM .
ANALYTICAL CHEMISTRY, 1990, 62 (11) :1111-1117
[32]   ELECTRON-TRANSFER PATHWAYS IN AMPEROMETRIC BIOSENSORS - FERROCENE-MODIFIED ENZYMES ENTRAPPED IN CONDUCTING-POLYMER LAYERS [J].
SCHUHMANN, W .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (1-2) :181-193
[33]   CONDUCTING POLYMER-BASED AMPEROMETRIC ENZYME ELECTRODES - TOWARDS THE DEVELOPMENT OF MINIATURIZED REAGENTLESS BIOSENSORS [J].
SCHUHMANN, W ;
KRANZ, C ;
HUBER, J ;
WOHLSCHLAGER, H .
SYNTHETIC METALS, 1993, 61 (1-2) :31-35
[34]   AMPEROMETRIC SUBSTRATE DETERMINATION IN FLOW-INJECTION SYSTEMS WITH POLYPYRROLE ENZYME ELECTRODES [J].
SCHUHMANN, W .
SENSORS AND ACTUATORS B-CHEMICAL, 1991, 4 (1-2) :41-49
[35]   Electrochemical characterization of polypyrrole glucose oxidase biosensor .2. Optimal preparation conditions for the biosensor [J].
Shin, MC ;
Kim, HS .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (1-2) :171-178
[36]   ENZYME-BASED BILAYER CONDUCTING POLYMER ELECTRODES CONSISTING OF POLYMETALLOPHTHALOCYANINES AND POLYPYRROLE GLUCOSE-OXIDASE THIN-FILMS [J].
SUN, ZS ;
TACHIKAWA, H .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1112-1117
[37]  
Suye S, 1998, BIOTECHNOL APPL BIOC, V27, P245
[38]   BIOSENSORS BASED ON OXIDASES IMMOBILIZED IN VARIOUS CONDUCTING POLYMERS [J].
TROJANOWICZ, M ;
GESCHKE, O ;
KRAWCZYK, TKV ;
CAMMANN, K .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 28 (03) :191-199
[39]   MINIATURIZED MULTIENZYME BIOSENSORS INTEGRATED WITH PH SENSORS ON FLEXIBLE POLYMER CARRIERS FOR INVIVO APPLICATIONS [J].
URBAN, G ;
JOBST, G ;
KEPLINGER, F ;
ASCHAUER, E ;
TILADO, O ;
FASCHING, R ;
KOHL, F .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (10) :733-739
[40]   Electropolymerization of pyrrole and immobilization of glucose oxidase in a flow system: influence of the operating conditions on analytical performance [J].
Vidal, JC ;
Garcia, E ;
Castillo, JR .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4) :371-382