Electrochemical preparation of brilliant-blue-modified poly(diallyldimethylammonium chloride) and Nafion-coated glassy carbon electrodes and their electrocatalytic behavior towards oxygen and L-cysteine

被引:41
作者
Chen, Shen-Ming [1 ]
Chen, Ji-Yan [1 ]
Thangannithu, R. [1 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, Taipei 106, Taiwan
关键词
brilliant blue FCF; Nafion; PDDAC; EQCM; RRDE; oxygen; L-cysteine;
D O I
10.1002/elan.200804213
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
Brilliant blue FCF-modified glassy carbon electrodes have been prepared by cycling the Nafion (or poly(diallyldimethylammonium chloride) (PDDAC)) coated electrodes repeatedly 15 cycles in brilliant blue FCF (BB FCF) dye solution. The BB FCF molecules are incorporated into Nafion coating by cycling the film-covered electrode between +0.3 to 1.2 V (vs. Ag/AgCl) in pH 1.5 BB FCF solution while PDDAC-coated electrode cycled between 0 to - 1.0 V (vs. Ag/AgCl) in pH 6.5 BB FCF solution to immobilize the dye. Electrostatic interaction between dye molecule and PDDAC was predominant in PDDAC coating whereas immobilization of dye in Nafion film attributed to the combined effect of electrostatic and hydrophobic interactions. ne voltammetric features of BB FCF-modified electrodes resemble that of surf ace-confined redox couples. The peak potentials of BB FCF-incorporated PDDAC-coated electrode were shifted to more positive potential region with decreasing pH of contacting solution. BB FCF-modified electrodes showed electrocatalytic activity towards reduction of oxygen and oxidation of L-cysteine with significant decease of overvoltage compared to unmodified electrode. The BB FCF-modified Nafion-coated electrode was tested for its analytical applications toward determination of L-cysteine. The linear range of calibration plot at BB FCF-modified Nafion-coated electrode is 10 to 100 mu M, which coincides with L-cysteine levels in biological fluids. Sensitivity and detection limit of the electrode are 111 nA mu M-1 and 0.5 mu M, respectively.
引用
收藏
页码:1565 / 1573
页数:9
相关论文
共 52 条
[1]
Cobalt(II) salophen-modified carbon-paste electrode for potentiometric and voltammetric determination of cysteine [J].
Amini, MK ;
Khorasani, JH ;
Khaloo, SS ;
Tangestaninejad, S .
ANALYTICAL BIOCHEMISTRY, 2003, 320 (01) :32-38
[2]
ANDERSSON A, 1993, CLIN CHEM, V39, P1590
[3]
[Anonymous], MODERN POLAGRAPHIC M
[4]
BARD AJ, 1980, ELECTROCHEMICAL METH, P521
[5]
Assays for total homocysteine and other thiols by capillary electrophoresis-laser-induced fluorescence detection I.: Preanalytical condition studies [J].
Caussé, E ;
Issac, C ;
Malatray, P ;
Bayle, C ;
Valdiguié, P ;
Salvayre, R ;
Couderc, F .
JOURNAL OF CHROMATOGRAPHY A, 2000, 895 (1-2) :173-178
[6]
Oxidation of L-cysteine at a fluorosurfactant-modified gold electrode: Lower overpotential and higher selectivity [J].
Chen, Zuofeng ;
Zheng, Huzhi ;
Lu, Chao ;
Zu, Yanbing .
LANGMUIR, 2007, 23 (21) :10816-10822
[7]
HIV-INDUCED CYSTEINE DEFICIENCY AND T-CELL DYSFUNCTION - A RATIONALE FOR TREATMENT WITH N-ACETYLCYSTEINE [J].
DROGE, W ;
ECK, HP ;
MIHM, S .
IMMUNOLOGY TODAY, 1992, 13 (06) :211-214
[8]
Electrochemical behavior Of L-cysteine and its detection at carbon nanotube electrode modified with platinum [J].
Fei, SD ;
Chen, JH ;
Yao, SZ ;
Deng, GH ;
He, DL ;
Kuang, YF .
ANALYTICAL BIOCHEMISTRY, 2005, 339 (01) :29-35
[9]
Electrochemical response of new carbon electrodes bulk modified with cobalt phthalocyanine to some thiols in the presence of heptane or human urine [J].
Filanovsky, B .
ANALYTICA CHIMICA ACTA, 1999, 394 (01) :91-100
[10]
BRILLIANT BLUE FCF AS A DYE TRACER FOR SOLUTE TRANSPORT STUDIES - A TOXICOLOGICAL OVERVIEW [J].
FLURY, M ;
FLUHLER, H .
JOURNAL OF ENVIRONMENTAL QUALITY, 1994, 23 (05) :1108-1112