Cobalt(II) salophen-modified carbon-paste electrode for potentiometric and voltammetric determination of cysteine

被引:131
作者
Amini, MK [1 ]
Khorasani, JH [1 ]
Khaloo, SS [1 ]
Tangestaninejad, S [1 ]
机构
[1] Univ Isfahan, Dept Chem, Esfahan 8174673441, Iran
关键词
modified electrode; sensors; carbon-paste electrode; potentiometric sensor; cysteine; cobalt(II) salophen;
D O I
10.1016/S0003-2697(03)00355-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A chemically modified electrode constructed by incorporating N,N'-bis(salicylidene)-1,2-phenylenediaminocobalt(II) into carbon-paste matrix was used as a sensitive electrochemical sensor for detection of cysteine. The resulting electrode exhibits catalytic properties for the electrooxidation of cysteine and lowers the overpotential for the oxidation of this compound. The faster rate of electron transfer results in a near-Nernstian behavior of the modified electrode and makes it a suitable potentiometric and voltammetric sensor for the fast and easy determination of cysteine. A linear response in concentration range from similar to2 muM to 0.01 M was obtained with a detection limit of 1 muM for the potentiometric detection of cysteine. The modified electrode was also used for the amperometric and differential pulse voltammetric determination of cysteine and the results were compared with those of the potentiometric method. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:32 / 38
页数:7
相关论文
共 46 条
[1]  
Aguirre MJ, 1998, ELECTROANAL, V10, P571
[2]   DUAL ELECTRODE LIQUID-CHROMATOGRAPHY DETECTOR FOR THIOLS AND DISULFIDES [J].
ALLISON, LA ;
SHOUP, RE .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :8-12
[3]  
Anderson JL, 1996, ANAL CHEM, V68, pR379, DOI 10.1021/a1960015y
[4]   Electrochemical detection of NADH and dopamine in flow analysis based on tetraruthenated porphyrin modified electrodes [J].
Angnes, L ;
Azevedo, CMN ;
Araki, K ;
Toma, HE .
ANALYTICA CHIMICA ACTA, 1996, 329 (1-2) :91-95
[5]  
BARD AJ, 1980, ELECTROCHEMICAL METH
[6]   Porphyrins in analytical chemistry. A review [J].
Biesaga, M ;
Pyrzynska, K ;
Trojanowicz, M .
TALANTA, 2000, 51 (02) :209-224
[7]   DIOXYGEN AFFINITIES OF SYNTHETIC COBALT SCHIFF-BASE COMPLEXES [J].
CHEN, D ;
MARTELL, AE .
INORGANIC CHEMISTRY, 1987, 26 (07) :1026-1030
[8]   DYNAMICS OF THE ELECTROCATALYTIC OXIDATION OF CYSTEINE AT NAFION FILM COATED ELECTRODES [J].
CHEN, XM ;
XIA, B ;
HE, PX .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 281 (1-2) :185-198
[9]   Flow injection-pulse amperometric detection of ephedrine at a cobalt phthalocyanine modified carbon paste electrode [J].
Cookeas, EG ;
Efstathiou, CE .
ANALYST, 2000, 125 (06) :1147-1150
[10]   Electrochemical and spectroscopic characterization of anodically formed nickel salen polymer films on glassy carbon, platinum, and optically transparent tin oxide electrodes in acetonitrile containing tetramethylammonium tetrafluoroborate [J].
Dahm, CE ;
Peters, DG ;
Simonet, J .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 410 (02) :163-171