High throughput bioanalytical LC/MS/MS determination of benzodiazepines in human urine: 1000 samples per 12 hours

被引:113
作者
Zweigenbaum, J [1 ]
Heinig, K [1 ]
Steinborner, S [1 ]
Wachs, T [1 ]
Henion, J [1 ]
机构
[1] Cornell Univ, New York State Coll Vet Med, Ithaca, NY 14850 USA
关键词
D O I
10.1021/ac9813540
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical capabilities of liquid chromatography tandem mass spectrometry for sensitive and highly selective determination of target compounds in complex biological samples makes it well suited for high-throughput analysis. We report the fast separation of size benzodiazepines isolated from human urine via selected reaction monitoring liquid chromatography/mass spectrometry using short dwell times to accommodate fast-eluting chromatographic peaks. The analytes Fc ere extracted from human urine samples along with their deuterium-labeled internal standards by a simple liquid-liquid ex-traction in 96-well plates. Using four autosamplers coupled to one chromatographic column and one tandem mass spectrometer operated in the turbo ion spray mode with positive ion detection, 1152 samples (12 96-well plates) were analyzed in less than 12 h. Through an electronic sn;itching box designed and constructed in-house, the autosamplers were synchronized with the mass spectrometer so that injections were made as soon as the mass spectrometer was ready to collect data. Each run required 30 s to complete with another 7-8 s for the data system to load the next data file to be collected. Chromatographic integrity and ion current response remained relatively constant for the duration of the analyses. The results show acceptable precision and accuracy and demonstrate the feasibility of using fast separations with tandem mass spectrometry for high-throughput analysis of biological samples containing multiple analytes.
引用
收藏
页码:2294 / 2300
页数:7
相关论文
共 41 条
  • [11] DIVERSOMERS - AN APPROACH TO NONPEPTIDE, NONOLIGOMERIC CHEMICAL DIVERSITY
    DEWITT, SH
    KIELY, JS
    STANKOVIC, CJ
    SCHROEDER, MC
    CODY, DMR
    PAVIA, MR
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (15) : 6909 - 6913
  • [12] Floyd CD, 1996, CHEM BRIT, V32, P31
  • [13] Cassette dosing: rapid in vivo assessment of pharmacokinetics
    Frick, LW
    Adkison, KK
    Wells-Knecht, KJ
    Woollard, P
    Higton, DM
    [J]. PHARMACEUTICAL SCIENCE & TECHNOLOGY TODAY, 1998, 1 (01): : 12 - 18
  • [14] Applications of the Caco-2 model in the design and development of orally active drugs: Elucidation of biochemical and physical barriers posed by the intestinal epithelium
    Gan, LSL
    Thakker, DR
    [J]. ADVANCED DRUG DELIVERY REVIEWS, 1997, 23 (1-3) : 77 - 98
  • [15] GILBERT JD, 1998, METHODOL SURV BIOANA, V25, P235
  • [16] High-throughput flow injection analysis mass spectroscopy with networked delivery of color rendered results.: 2.: Three-dimensional spectral mapping of 96-well combinatorial chemistry racks
    Görlach, E
    Richmond, R
    Lewis, I
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (15) : 3227 - 3234
  • [17] AN ULTRA RAPID AND SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR DETERMINATION OF TISSUE AND PLASMA-FREE AMINO-ACIDS
    GRASER, TA
    GODEL, HG
    ALBERS, S
    FOLDI, P
    FURST, P
    [J]. ANALYTICAL BIOCHEMISTRY, 1985, 151 (01) : 142 - 152
  • [18] Automated 96-well solid phase extraction for the determination of doramectin in cattle plasma
    Harrison, AC
    Walker, DK
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (05) : 777 - 783
  • [19] Hegy G, 1996, RAPID COMMUN MASS SP, V10, P1894, DOI 10.1002/(SICI)1097-0231(199612)10:15<1894::AID-RCM708>3.0.CO
  • [20] 2-2