Improved delivery efficiency for step and shoot intensity modulated radiotherapy using a fast-tuning magnetron

被引:12
作者
Budgell, GJ [1 ]
Martens, C
Claus, F
机构
[1] Christie Hosp NHS Trust, Manchester M20 4BX, Lancs, England
[2] Ghent Univ Hosp, Div Radiotherapy, B-9000 Ghent, Belgium
关键词
D O I
10.1088/0031-9155/46/11/402
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The delivery efficiency of step and shoot intensity modulated radiotherapy (IMRT) has been improved by the installation of fast-tuning magnetrons into three travelling wave linear accelerators. The IMRT delivery efficiency and the beam start-up performance have been compared before and after installation. Start-up and inter sub-field times were reduced by an average of 3.0 s. A typical start-up time from depression of the start button to beam on is now around 4 s. Delivery efficiency for a variety of clinical and quality control prescriptions was improved by an average of 30.7% (range 7.4-60.9%), depending on a complex combination of the number of sub-fields, distance moved by leaves and dose rate. For the oldest accelerator (7 years old), dosimetric accuracy was significantly improved for low dose sub-fields. The dose output was within 2% for a 1 monitor unit (MU) sub-field and 1% for a 2 MU sub-field. The two newer accelerators displayed similar or better dose characteristics even before fast-tuning, magnetron installation. Beam symmetries and flatnesses were acceptable at all energies and dose rates, and showed no obvious degradation in low dose sub-fields. It is recommended that fast-tuning magnetrons are adopted for accelerators of this design performing step and shoot IMRT.
引用
收藏
页码:N253 / N261
页数:9
相关论文
共 7 条
[1]   Startup performance of the traveling wave versus standing wave linear accelerator [J].
Buchgeister, M ;
Nusslin, F .
MEDICAL PHYSICS, 1998, 25 (04) :493-495
[2]  
Grosser KH, 2000, USE OF COMPUTERS IN RADIATION THERAPY, P308
[3]   Quality assurance of the dose delivered by small radiation segments [J].
Hansen, VN ;
Evans, PM ;
Budgell, GJ ;
Mott, JHL ;
Williams, PC ;
Brugmans, MJP ;
Wittkamper, FW ;
Mijnheer, BJ ;
Brown, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (09) :2665-2675
[4]  
*I PHYS ENG MED, 1999, 81 IPEM
[5]   Intensity modulation with the "step and shoot" technique using a commercial MLC:: A planning study [J].
Keller-Reichenbecher, MA ;
Bortfeld, T ;
Levegrün, S ;
Stein, J ;
Preiser, K ;
Schlegel, W .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (05) :1315-1324
[6]   Monitor unit settings for intensity modulated beams delivered using a step-and-shoot approach [J].
Sharpe, MB ;
Miller, BM ;
Yan, D ;
Wong, JW .
MEDICAL PHYSICS, 2000, 27 (12) :2719-2725
[7]   Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments [J].
Xia, P ;
Verhey, LJ .
MEDICAL PHYSICS, 1998, 25 (08) :1424-1434