Comparative analysis of early and late angiographic outcomes using two quantitative algorithms in the balloon versus optimal atherectomy trial (BOAT)

被引:7
作者
Lansky, AJ
Popma, JJ
Cutlip, D
Ho, KKL
Abizaid, AS
Saucedo, J
Zhang, Y
Senerchia, C
Kuntz, RE
Leon, MB
Baim, DS
机构
[1] Washington Hosp Ctr, Dept Internal Med, Div Cardiol, Washington, DC 20010 USA
[2] Beth Israel Hosp, Dept Internal Med, Div Cardiol, Boston, MA 02215 USA
关键词
D O I
10.1016/S0002-9149(99)00166-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although substantial intersystem variability has been shown among several commercially available quantitative angiographic (QA) analysis algorithms, no previous study has compared the angiographic findings using 2 different QA systems performed at the same central angiographic laboratory. The purpose of this study was to compare the early and late QA results obtained with the CMS (MEDIS) and ARTREK (ImageComm) QA systems in the Balloon versus Optimal Atherectomy Trial. Directional atherectomy (n = 496) or balloon angioplasty (n = 490) was performed in 986 patients; late QA follow-vp was available in 767 patients (77.7%). QA analysis was performed by 2 independent observers using the CMS and ARTREK systems. Correlation between the 2 QA systems for baseline measurements was good (Pearson's R = 0.78), although the CMS system resulted in larger baseline reference diameter (RD) (3.22 +/- 0.45 vs 3.07 +/- 0.40 mm; p < 0.0001) and baseline minimal lumen diameters (MLD) (1.05 +/- 0.35 vs 0.92 +/- 0.32; mm p < 0.0001) than the ARTREK system. The final and follow-vp RD (+0.17 and + 0.11 mm, respectively) were also larger using the CMS system. In contrast, the final and follow-up measurements of MLD and percent diameter stenosis were not significantly different using the 2 QA systems. The QA system did not affect the ability to detect a difference in restenosis rates (>50% follow-up diameter stenosis) between the 2 treatment groups (CMS, directional atherectomy [31.8%]; balloon angioplasty [40.5%]; p = 0.013 and ARTREK, directional atherectomy [33.9%], balloon angioplasty [41.3%]; p = 0.036), Only lesion irregularity contributed to the difference in baseline measurements of MLD and percent diameter stenosis. We conclude that important differences in measurements of RD, baseline MLD, and percent diameter stenosis were noted using the CMS and ARTREK systems. Both systems, however, were able to detect a treatment benefit associated with directional atherectomy in BOAT. The comparability of other angiographic systems will require similar evaluation in other studies. (C) 1999 by Excerpta Medica, Inc.
引用
收藏
页码:1611 / 1616
页数:6
相关论文
共 21 条
[1]   A COMPARISON OF DIRECTIONAL ATHERECTOMY WITH BALLOON ANGIOPLASTY FOR LESIONS OF THE LEFT ANTERIOR DESCENDING CORONARY-ARTERY [J].
ADELMAN, AG ;
COHEN, EA ;
KIMBALL, BP ;
BONAN, R ;
RICCI, DR ;
WEBB, JG ;
LARAMEE, L ;
BARBEAU, G ;
TRABOULSI, M ;
CORBETT, BN ;
SCHWARTZ, L ;
LOGAN, AG .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (04) :228-233
[2]  
Baim DS, 1998, CIRCULATION, V97, P322
[3]  
FISCHMAN D, 1994, NEW ENGL J MED, P496
[4]   QUANTITATIVE AND QUALITATIVE CORONARY ANGIOGRAPHIC ANALYSIS - REVIEW OF METHODS, UTILITY, AND LIMITATIONS [J].
HERMILLER, JB ;
CUSMA, JT ;
SPERO, LA ;
FORTIN, DF ;
HARDING, MB ;
BASHORE, TM .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 25 (02) :110-131
[5]   VARIABILITY IN MEASURES OF CORONARY LUMEN DIMENSIONS USING QUANTITATIVE CORONARY ANGIOGRAPHY [J].
HERRINGTON, DM ;
SIEBES, M ;
SOKOL, DK ;
SIU, CO ;
WALFORD, GD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) :1068-1074
[6]   COMPARATIVE VALIDATION OF QUANTITATIVE CORONARY ANGIOGRAPHY SYSTEMS - RESULTS AND IMPLICATIONS FROM A MULTICENTER STUDY USING A STANDARDIZED APPROACH [J].
KEANE, D ;
HAASE, J ;
SLAGER, CJ ;
VANSWIJNDREGT, EM ;
LEHMANN, KG ;
OZAKI, Y ;
DIMARIO, C ;
KIRKEEIDE, R ;
SERRUYS, PW .
CIRCULATION, 1995, 91 (08) :2174-2183
[7]  
Koning G, 1992, Int J Card Imaging, V8, P153, DOI 10.1007/BF01137536
[8]  
Lansky AJ, 1998, TXB INTERVENTIONAL C, P725
[9]   AUTOMATED QUANTITATIVE CORONARY ARTERIOGRAPHY - MORPHOLOGICAL AND PHYSIOLOGICAL VALIDATION IN VIVO OF A RAPID DIGITAL ANGIOGRAPHIC METHOD [J].
MANCINI, GBJ ;
SIMON, SB ;
MCGILLEM, MJ ;
LEFREE, MT ;
FRIEDMAN, HZ ;
VOGEL, RA .
CIRCULATION, 1987, 75 (02) :452-460
[10]  
REIBER J, 1996, CARDIOVASCULAR IMAGI, V1, P39