Double-balloon endoscopy for the diagnosis and treatment of small intestinal disease

被引:34
作者
Kita, H [1 ]
Yamamoto, H [1 ]
机构
[1] Jichi Med Sch, Dept Internal Med, Minami Kawachi, Tochigi 3290498, Japan
关键词
double-balloon endoscopy; small intestine; endoscopic treatment;
D O I
10.1016/j.bpg.2005.09.004
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Evaluation of the small bowel has long been hampered because of its long and multiple complex loop configurations. Yamamoto et al have developed a new method of inserting an endoscope, known as the double-balloon method of enteroscopy, the Fujinon double-balloon endoscopy system being specialised for this application. Two types of endoscope are currently available for this technique. The EN-450 P5 is a thin endoscope for regular use, whereas the EN-450 T5 is a therapeutic double-balloon endoscope with a larger accessory channel of 2.8 mm in diameter. Double-balloon endoscopy enables visualisation of the entire small bowel and also allows for interventional therapy in the small intestine. This method can be used either from an oral or an anal insertion. Observation of an affected area with controlled movement of the endoscope enables interventions, including biopsies, haemostasis, balloon dilatation, stent placement, polypectomy and endoscopic mucosal resection, to be performed. In our large study series, it was demonstrated that double-balloon endoscopy permitted exploration of the small intestine with the high success rate of total enteroscopy. The procedure is safe and useful, and it provides high diagnostic yields and therapeutic capabilities.
引用
收藏
页码:179 / 194
页数:16
相关论文
共 26 条
[1]   A randomized trial comparing wireless capsule endoscopy with push enteroscopy for the detection of small-bowel lesions [J].
Appleyard, M ;
Fireman, Z ;
Glukhovsky, A ;
Jacob, H ;
Shreiver, R ;
Kadirkamanathan, S ;
Lavy, A ;
Lewkowicz, S ;
Scapa, E ;
Shofti, R ;
Swain, P ;
Zaretsky, A .
GASTROENTEROLOGY, 2000, 119 (06) :1431-1438
[2]   Does the insertion depth in push enteroscopy depend on the working length of the enteroscope? [J].
Benz, C ;
Jakobs, R ;
Riemann, JF .
ENDOSCOPY, 2002, 34 (07) :543-545
[3]   Do we need the overtube for push-enteroscopy? [J].
Benz, C ;
Jakobs, R ;
Riemann, JF .
ENDOSCOPY, 2001, 33 (08) :658-661
[4]  
BERNER JS, 1994, AM J GASTROENTEROL, V89, P2139
[5]   A prospective trial comparing small bowel radiographs and video capsule endoscopy for suspected small bowel disease [J].
Costamagna, G ;
Shah, SK ;
Riccioni, ME ;
Foschia, F ;
Mutignani, M ;
Perri, V ;
Vecchioli, A ;
Brizi, MG ;
Picciocchi, A ;
Marano, P .
GASTROENTEROLOGY, 2002, 123 (04) :999-1005
[6]   Cutting the cord for capsule endoscopy [J].
Faigel, DO ;
Fennerty, MB .
GASTROENTEROLOGY, 2002, 123 (04) :1385-1388
[7]   Bleeding polyp in the mid small intestine identified by capsule endoscopy and treated by double-balloon endoscopy [J].
Kita, H ;
Yamamoto, H ;
Nakamura, T ;
Shirakawa, K ;
Terano, A ;
Sugano, K .
GASTROINTESTINAL ENDOSCOPY, 2005, 61 (04) :628-629
[8]  
KUNO A, 2004, GASTROINTEST ENDOSC, P60
[9]   Safety of capsule endoscopy in patients with pacemakers [J].
Leighton, JA ;
Sharma, VK ;
Srivathsan, K ;
Heigh, RI ;
McWane, TL ;
Post, JK ;
Robinson, SR ;
Bazzell, JL ;
Fleischer, DE .
GASTROINTESTINAL ENDOSCOPY, 2004, 59 (04) :567-569
[10]   Double-balloon enteroscopy: Preliminary experience in patients with obscure gastrointestinal bleeding or chronic abdominal pain [J].
May, A ;
Nachbar, L ;
Wardak, A ;
Yamamoto, H ;
Ell, C .
ENDOSCOPY, 2003, 35 (12) :985-991