Use of a nerve stimulator does not improve the efficacy of ultrasound-guided supraclavicular nerve blocks

被引:55
作者
Beach, Michael L. [1 ]
Sites, Brian D. [1 ]
Gallagher, John D. [1 ]
机构
[1] Dartmouth Hitchcock Med Ctr, Dartmouth Med Sch, Dept Anesthesiol, Lebanon, NH 03756 USA
关键词
anesthesia; regional; nerve stimulator; supraclavicular block; ultrasound;
D O I
10.1016/j.jclinane.2006.03.017
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To evaluate the efficacy of nerve stimulation as an adjunct to ultrasound-guided supraclavicular nerve blocks. Design: Prospective database review. Setting: Tertiary-care medical center. Measurements: The records of 94 consecutive adult patients requiring surgery below the elbow and consenting to receive regional anesthesia were studied. The focus of this study was on supraclavicular nerve block using ultrasound guidance for nerve identification and needle localization. A nerve stimulator with a motor response lower than 0.5 mA was used for confirmation of findings. An ultrasound image was considered adequate if two trunks of the brachial plexus were visualized and if the needle was completely seen on the long axis. A successful block was defined as one that sufficed as the sole anesthetic without conversion to general anesthesia. Motor and sensory examination findings on the upper extremity were also evaluated. Results: 74 patients had an adequate ultrasound image. Of the 64 patients with a positive motor response, 88% had a successful block, as compared with 90% of the 10 patients without a motor response (relative risk, 1.09; 95% confidence interval, 0.79-1.51; P = 0.52). Neither multivariate correction for baseline characteristics nor inclusion of the 20 patients with inadequate ultrasound images changed the results. Conclusion: For adequately imaged ultrasound-guided supraclavicular nerve blocks, a positive motor response to nerve stimulation does not increase the success rate of the block. In addition, the high false-negative rate suggests that these blocks are usually effective, even in the absence of a motor response. Nerve stimulation as an adjunct to ultrasound guidance may have a limited role. (C) 2006 Published by Elsevier Inc.
引用
收藏
页码:580 / 584
页数:5
相关论文
共 9 条
[1]   Ultrasound-guided supraclavicular brachial plexus block [J].
Chan, VWS ;
Perlas, A ;
Rawson, R ;
Odukoya, O .
ANESTHESIA AND ANALGESIA, 2003, 97 (05) :1514-1517
[2]   What is the relationship between paresthesia and nerve stimulation for axillary brachial plexus block? [J].
Choyce, A ;
Chan, VWS ;
Middleton, WJ ;
Knight, PR ;
Peng, P ;
McCartney, CJL .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2001, 26 (02) :100-104
[3]   Nerve stimulator and multiple injection technique for upper and lower limb blockade: Failure rate, patient acceptance, and neurologic complications [J].
Fanelli, G ;
Casati, A ;
Garancini, P ;
Torri, G .
ANESTHESIA AND ANALGESIA, 1999, 88 (04) :847-852
[4]   The ultrasonographic appearance of the femoral nerve and cases of iatrogenic impairment [J].
Gruber, H ;
Peer, S ;
Kovacs, P ;
Marth, R ;
Bodner, G .
JOURNAL OF ULTRASOUND IN MEDICINE, 2003, 22 (02) :163-172
[5]   Painful paresthesiae are infrequent during brachial plexus localization using low-current peripheral nerve stimulation [J].
Karaca, P ;
Hadzic, A ;
Yufa, M ;
Vloka, JD ;
Brown, AR ;
Visan, A ;
Sanborn, K ;
Santos, AC .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2003, 28 (05) :380-383
[6]   Sedation with sufentanil and midazolam decreases pain in patients undergoing upper limb surgery under multiple nerve block [J].
Kinirons, BP ;
Bouaziz, H ;
Paqueron, X ;
Ababou, A ;
Jandard, C ;
Cao, MM ;
Bur, ML ;
Laxenaire, MC ;
Benhamou, D .
ANESTHESIA AND ANALGESIA, 2000, 90 (05) :1118-1121
[7]  
Sia S, 2000, ANESTH ANALG, V91, P647
[8]   Ultrasound-guided popliteal block demonstrates an atypical motor response to nerve stimulation in 2 patients with diabetes mellitus [J].
Sites, BD ;
Gallagher, J ;
Sparks, M .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2003, 28 (05) :479-482
[9]   Inability to consistently elicit a motor response following sensory paresthesia during interscalene block administration [J].
Urmey, WF ;
Stanton, J .
ANESTHESIOLOGY, 2002, 96 (03) :552-554