Ovarian function during use of Nestorone® subdermal implants

被引:26
作者
Brache, V
Massai, R
Mishell, DR
Moo-Young, AJ
Alvarez, F
Salvatierra, AM
Cochon, L
Croxatto, H
Robbins, A
Faundes, A
机构
[1] PROFAMILIA, Biomed Res Dept, Santo Domingo, Dominican Rep
[2] Inst Chileno Med Reproduct, Santiago, Chile
[3] Univ So Calif, Keek Sch Med, Los Angeles, CA USA
[4] Populat Council, Biomed Res Ctr, New York, NY USA
关键词
Nestorone (R) implants; ovarian function; luteal activity; persistent follicles;
D O I
10.1016/S0010-7824(00)00092-5
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Nestorone(R) progestin (NES) is a potent 19-nor-progesterone derivative which is biologically inactive when administered orally; however it is an excellent option for implant contraception. The objective of this study was to evaluate ovarian function during use of either one 4-cm or two 3-cm NES implants for 24 months. A total of 60 volunteers were enrolled in each dose group. Vaginal ultrasound (VUS) and blood sampling for determinations of estradiol (E-2), progesterone (P) and NES serum levels were carried out twice a week for 6 consecutive weeks, beginning in months 1, 6, 12, 18, and 24 of implant use. Serum levels of NES declined with time, with a more pronounced decrease during the first 18 months of implant use; thereafter, NES levels remained stable until the end of the study at 24 months. Luteal activity was very infrequent during the first year of use (<3%) but increased during the second year, occurring in 27% anti 35% of the sampling periods in the 1-implant group, and 2% and 16% of the sampling periods in the 2-implant group, at months 18 find 24 of use, respectively. No luteal activity was observed with NES levels above 80 pmol/L. Serum P levels in periods of luteal activity were significantly lower than those of controls. Persistant anovulatory Follicles were the most common VUS finding and this was associated with E-2 levels that remained within the normal range (101-1500 pmol/L) in the majority of the sampling periods studied. Considering that a single implant offers advantage for insertion and removal, a new single NES implant is being developed with a slightly higher release rate, to reduce effectively the incidence of ovulation and provide a greater margin of safety beyond 2 years. CONTRACEPTION 2000;61:199-204 (C) 2000 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 34 条
[11]  
DIAZ S, 1993, CURR OPIN OBSTET GYN, V5, P815
[12]   CLINICAL-TRIAL WITH NESTORONE(TM) SUBDERMAL CONTRACEPTIVE IMPLANTS [J].
DIAZ, S ;
SCHIAPPACASSE, V ;
PAVEZ, M ;
ZEPEDA, A ;
MOOYOUNG, AJ ;
BRANDEIS, A ;
LAHTEENMAKI, P ;
CROXATTO, HB .
CONTRACEPTION, 1995, 51 (01) :33-38
[13]  
Faundes A, 1996, HUM REPROD, V11, P114
[14]   Norplant® consensus statement and background review [J].
Fraser, IS ;
Tiitinen, A ;
Affandi, B ;
Brache, V ;
Croxatto, HB ;
Diaz, S ;
Ginsburg, J ;
Gu, SJ ;
Holma, P ;
Johansson, E ;
Meirik, O ;
Mishell, DR ;
Nash, HA ;
von Schoultz, B ;
Sivin, I .
CONTRACEPTION, 1998, 57 (01) :1-9
[15]   CONTRACEPTION WITH SUBDERMAL IMPLANTS RELEASING THE PROGESTIN ST-1435 - A DOSE-FINDING STUDY [J].
HAUKKAMAA, M ;
LAURIKKAROUTTI, M ;
HEIKINHEIMO, O ;
MOOYOUNG, A .
CONTRACEPTION, 1992, 45 (01) :49-55
[16]   PHARMACODYNAMICS OF A CONTRACEPTIVE VAGINAL RING RELEASING 3-KETO-DESOGESTREL [J].
JACKSON, R ;
NEWTON, JR .
CONTRACEPTION, 1989, 39 (06) :653-664
[17]   CONTRACEPTION WITH SUBDERMAL ST-1435 CAPSULES - SIDE-EFFECTS, ENDOCRINE PROFILES AND LIVER-FUNCTION RELATED TO DIFFERENT LENGTHS OF CAPSULES [J].
KURUNMAKI, H ;
TOIVONEN, J ;
LAHTEENMAKI, P ;
LUUKKAINEN, T .
CONTRACEPTION, 1985, 31 (03) :305-318
[18]  
LADIPO O, 1994, CURR OPIN OBSTET GYN, V6, P564
[19]  
LAHTEENMAKI P, 1981, CONTRACEPTION, V23, P63
[20]   PITUITARY AND OVARIAN-FUNCTION DURING CONTRACEPTION WITH ONE SUBCUTANEOUS IMPLANT RELEASING A-PROGESTIN, ST-1435 [J].
LAHTEENMAKI, P ;
WEINER, E ;
LAHTEENMAKI, P ;
JOHANSSON, EDB ;
LUUKKAINEN, T .
CONTRACEPTION, 1982, 25 (03) :299-306