Evaluation of myocardial infarct size in rat heart by pinhole SPECT

被引:35
作者
Hirai, T
Nohara, R [1 ]
Hosokawa, R
Tanaka, M
Inada, H
Fujibayashi, Y
Fujita, M
Konishi, J
Sasayama, S
机构
[1] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Med, Sakyo Ku, Kyoto 6068397, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Pharmacol, Kyoto 6068397, Japan
[3] Kyoto Univ, Grad Sch Med, Dept Nucl Med, Kyoto 6068397, Japan
关键词
pinhole SPECT; myocardial infarction; myocardial perfusion;
D O I
10.1016/S1071-3581(00)90030-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. High-resolution single photon emission computed tomography (SPECT) with a pinhole collimator is a new method for evaluating the regional properties of radiopharmaceuticals in small laboratory animals in vivo. Although several reports of normal images of rat taken by this new technique are available, there are as yet few reports on its use in disease models, such as myocardial infarction, In this study, we clearly visualized myocardial flow in the rat heart with myocardial infarction using this system, and evaluated the relationship between SPECT images and histologic analysis. Methods and Results, For visualization of myocardial flow in rat heart, Tl-201 images were taken just before and 24 days after left coronary artery ligation, The images were taken using a 4-head SPECT scanner with pinhole collimators. The percent infarct size on Tl-201-SPECT imaging (%SI) and the defect score were then assessed and compared with the percent infarct size on histologic analysis (%HI). Both the %SI and defect score correlated well with %HI (r = 0.97 and 0.74, respectively). Conclusion. Serial SPECT imaging using pinhole collimators permits estimates of myocardial flow even in small laboratory animals noninvasively in vivo.
引用
收藏
页码:107 / 111
页数:5
相关论文
共 14 条
[1]  
FISHBEIN MC, 1978, AM J PATHOL, V90, P57
[2]  
ISHIZU K, 1995, J NUCL MED, V36, P2282
[3]  
Iwasaki T, 1996, J NUCL MED, V37, P680
[4]  
JASZCZAK RJ, 1993, J NUCL MED, V34, pP9
[5]  
KAUFMAN N, 1959, ARCH PATHOL, V67, P482
[6]   A FILTERED BACKPROJECTION ALGORITHM FOR PINHOLE SPECT WITH A DISPLACED CENTER OF ROTATION [J].
LI, JY ;
JASZCZAK, RJ ;
GREER, KL ;
COLEMAN, RE .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (01) :165-176
[7]   PINHOLE EMISSION COMPUTED-TOMOGRAPHY - METHOD AND EXPERIMENTAL EVALUATION [J].
PALMER, J ;
WOLLMER, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (03) :339-350
[8]  
SEYLE H, 1960, ANGIOLOGY, V11, P398
[9]  
VAQUER R A, 1987, Journal of Nuclear Medicine, V28, P678
[10]  
WEBER DA, 1994, J NUCL MED, V35, P342