Feasibility of simultaneous intracranial EEG-fMRI in humans: A safety study

被引:73
作者
Carmichael, David W. [1 ]
Thornton, John S. [2 ]
Rodionov, Roman
Thornton, Rachel
McEvoy, Andrew W. [3 ]
Ordidge, Roger J. [4 ]
Allen, Philip J. [5 ]
Lemieux, Louis
机构
[1] UCL, Inst Neurol, Adv Magnet Resonance Imaging Grp, Dept Clin & Expt Epilepsy, London WC1N 3AR, England
[2] Natl Hosp Neurol & Neurosurg, Lysholm Dept Neuroradiol, London WC1N 3BG, England
[3] Natl Hosp Neurol & Neurosurg, Victor Horsley Dept Neurosurg, London WC1N 3BG, England
[4] UCL, Dept Med Phys & Bioengn, London WC1N 3AR, England
[5] Natl Hosp Neurol & Neurosurg, Dept Clin Neurophysiol, London WC1N 3BG, England
关键词
Safety; EEG; fMRI; Intracranial EEG; Epilepsy; Simultaneous intracranial EEG-fMRI; DEEP BRAIN-STIMULATION; MR HEATING TESTS; NEUROSTIMULATION SYSTEMS; FUNCTIONAL MRI; EPILEPSY; TEMPERATURE; ELECTRODES; DISCHARGES; IMPLANT; PATIENT;
D O I
10.1016/j.neuroimage.2009.07.062
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In epilepsy patients who have electrodes implanted in their brains as part of their pre-surgical assessment, simultaneous intracranial EEG and fMRI (icEEG-fMRI) may provide important localising information and improve understanding of the underlying neuropathology. However, patient safety during icEEG-fMRI has not been addressed. Here the potential health hazards associated with icEEG-fMRI were evaluated theoretically and the main risks identified as: mechanical forces on electrodes from transient magnetic effects, tissue heating due to interaction with the pulsed RF fields and tissue stimulation due to interactions with the switched magnetic gradient fields. These potential hazards were examined experimentally in vitro on a Siemens 3 T Trio, 1.5 T Avanto and a GE 3 T Signa Excite scanner using a Brain Products MR compatible EEG system. No electrode flexion was observed. Temperature measurements demonstrated that heating well above guideline limits can occur. However heating could be kept within safe limits (<1.0 degrees C) by using a head transmit RF coil, ensuring EEG cable placement to exit the RF coil along its central z-axis, using specific EEG cable lengths and limiting MRI sequence specific absorption rates (SARs). We found that the risk of tissue damage due to RF-induced heating is low provided implant and scanner specific SAR limits are observed with a safety margin used to account for uncertainties (e.g. in scanner-reported SAR). The observed scanner gradient switching induced current (0.08 mA) and charge density (0.2 mu C/cm(2)) were well within safety limits (0.5 mA and 30 mu C/cm(2). respectively). Site-specific testing and a conservative approach to safety are required to avoid the risk of adverse events. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:379 / 390
页数:12
相关论文
共 56 条
[1]   Effects of magnetic resonance Imaging on cardiac pacemakers and electrodes [J].
Achenbach, S ;
Moshage, W ;
Diem, B ;
Bieberle, T ;
Schibgilla, V ;
Bachmann, K .
AMERICAN HEART JOURNAL, 1997, 134 (03) :467-473
[2]   CONSIDERATIONS FOR SAFETY WITH CHRONICALLY IMPLANTED NERVE ELECTRODES [J].
AGNEW, WF ;
MCCREERY, DB .
EPILEPSIA, 1990, 31 :S27-S32
[3]   Complications in the use of diathermy [J].
Aigner, N ;
Fialka, C ;
Fritz, A ;
Wruhs, O ;
Zoch, G .
BURNS, 1997, 23 (03) :256-264
[4]   Measuring local RF heating in MRI: Simulating perfusion in a perfusionless phantom [J].
Akca, Imran B. ;
Ferhanoglu, Onur ;
Yeung, Christopher J. ;
Guney, Sevin ;
Tasci, T. Onur ;
Atalar, Ergin .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (05) :1228-1235
[5]   Event-related fMRI of myoclonic jerks arising from dysplastic cortex [J].
Archer, John S. ;
Waites, Anthony B. ;
Abbott, David F. ;
Federico, Paolo ;
Jackson, Graeme D. .
EPILEPSIA, 2006, 47 (09) :1487-1492
[6]  
*ASTM INT, 2007, F218202A ASTM INT
[7]   Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating [J].
Baker, KB ;
Tkach, JA ;
Nyenhuis, JA ;
Phillips, M ;
Shellock, FG ;
Gonzalez-Martinez, J ;
Rezai, AR .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (02) :315-320
[8]   Neurostimulation systems: Assessment of magnetic field interactions associated with 1.5-and 3-Tesla MR systems [J].
Baker, KB ;
Nyenhuis, JA ;
Hrdlicka, G ;
Rezai, AR ;
Tkach, JA ;
Shellock, FG .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (01) :72-77
[9]   Variability in RF-induced heating of a deep brain stimulation implant across MR systems [J].
Baker, Kenneth B. ;
Tkach, Jean A. ;
Phillips, Micheal D. ;
Rezai, Ali R. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (06) :1236-1242
[10]   MRI-induced heating of selected thin wire metallic implants - laboratory and computational studies - findings and new questions raised [J].
Bassen, H ;
Kainz, W ;
Mendoza, G ;
Kellom, T .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2006, 15 (02) :76-84