Suture strength and angle of load application in a suture anchor eyelet

被引:40
作者
Deakin, M
Stubbs, D
Bruce, W
Goldberg, J
Gillies, RM
Walsh, WR [1 ]
机构
[1] Univ New S Wales, Prince Wales Hosp, Orthopaed Res Labs, Sydney, NSW 2031, Australia
[2] Orthosports, Randwick, NSW, Australia
关键词
suture anchor; suture material; anchor orientation; load to failure; bioabsorbable;
D O I
10.1016/j.arthro.2005.09.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To assess the effect of suture material, anchor orientation, and anchor eyelet design on the static loading properties of suture anchors. Type of Study: Biomechanical bench study. Methods: Two metallic suture anchors, Mitek GII (Mitek, Westwood, MA) and Corkscrew (Arthrex, Naples, FL) and a bioabsorbable anchor (Biocorkscrew; Arthrex) were tested with single strand of No. 2 Ethibond (Ethicon, Norderstedt, Germany) or No. 2 FiberWire (Arthrex) suture. Suture pull angle was varied through 0 degrees, 45 degrees, and 90 degrees with the anchor rotation angle in either a sagittal or coronal plane. Constructs were tested to failure using an MTS 858 Bionix testing machine (Material Testing b Systems, Eden Prairie, MN). Peak loads, stiffness, energy to peak load, and failure modes were determined for all samples. Results: FiberWire showed superior static mechanical properties when compared with single-strand Ethibond over all testing conditions (P < .05). Suture pull angle had a significant effect on load to failure with both metallic anchors but not on the bioabsorbable anchor (1 < .05). Conclusions: Suture pull angle and anchor rotation angle play an important role in the failure load of suture when placed in an eyelet. The polyaxial nature of the Biocorkscrew eyelet allows for increased degrees of freedom but introduces failure of the suture eyelet as a new failure mode. Clinical Relevance: The loading direction and placement of the suture anchor plays a role in the performance of the suture anchor-suture complex.
引用
收藏
页码:1447 / 1451
页数:5
相关论文
共 10 条
[1]
Suture anchors - Update 1999 [J].
Barber, FA ;
Herbert, MA .
ARTHROSCOPY, 1999, 15 (07) :719-725
[2]
The effect of suture anchor design and orientation on suture abrasion: An in vitro study [J].
Bardana, DD ;
Burks, RT ;
West, JR ;
Greis, PE .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (03) :274-281
[3]
THE DEADMAN THEORY OF SUTURE ANCHORS - OBSERVATIONS ALONG A SOUTH TEXAS FENCE LINE [J].
BURKHART, SS .
ARTHROSCOPY, 1995, 11 (01) :119-123
[4]
Experimental rotator cuff repair - A preliminary study [J].
Gerber, C ;
Schneeberger, AG ;
Perren, SM ;
Nyffeler, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (09) :1281-1290
[5]
Mechanical testing of absorbable suture anchors [J].
Meyer, DC ;
Fucentese, SF ;
Ruffieux, K ;
Jacob, HAC ;
Gerber, C .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (02) :188-193
[6]
Failure of suture material at suture anchor eyelets [J].
Meyer, DC ;
Nyffeler, RW ;
Fucentese, SF ;
Gerber, C .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (09) :1013-1019
[7]
Osteolysis after open shoulder stabilization using a new bioresorbable bone anchor:: A prospective, non-randomized clinical trial [J].
Müller, M ;
Kääb, MJ ;
Villiger, C ;
Holzach, P .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 :30-36
[8]
Full-thickness rotator cuff tears - A biomechanical comparison of suture versus bone anchor techniques [J].
Reed, SC ;
Glossop, N ;
OgilvieHarris, DJ .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1996, 24 (01) :46-48
[9]
A biomechanical evaluation of suture anchors in repair of the rotator cuff [J].
Rossouw, DJ ;
McElroy, BJ ;
Amis, AA ;
Emery, RJH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03) :458-461
[10]
Mechanical strength of arthroscopic rotator cuff repair techniques - An in vitro study [J].
Schneeberger, AG ;
Von Roll, A ;
Kalberer, F ;
Jacob, HAC ;
Gerber, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (12) :2152-2160